Hemo-Flow Double Lumen Catheter, Models HFS-24, HFS-28, HFS-32, HFS-36, HFS-40
Catheter, Hemodialysis, Implanted. 510(k) K994105, from Medical Components, Inc. (Harleysville, PA). Product code MSD, class 2.
As of Nov 22, 2026, K994105 is an FDA 510(k) held by Medical Components, Inc., substantially equivalent on Oct 3, 2001 after 667 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 667 days
- Recalls: 2
- Cited as a predicate by: 6 devices
The Medcomp Hemo-Flow Catheter is indicated for use in attaining long-term vascular access for hemodialysis and apheresis. It may be inserted percutaneously and is ideally placed in the internal jugular vein of an adult patient. Alternate insertion site includes the subclavian vein as required.
- Medcomp Ash Split-Cath 28CM, Medcomp Ash Split-Cath 32CMK972207 · Medcomp · Feb 23, 1998
- Nexsite HD Hemodialysis Catheter for Long Term Use (28CM) Nexsite HD Hemodialysis Catheter for Long Term Use (24CM)K121933 · Marvao Medical Devices, Ltd. · Mar 14, 2013
- AngioDynamics, Inc., Duramax Hemodialysis Catheter and Procedure KitK080400 · AngioDynamics, Inc. · May 13, 2008
- Novoflo Catheter LTK072499 · Novosci, Inc. · Oct 30, 2007
- Dermaport Percutaneous Vascular Access System (Pvas)K071202 · Dermaport, Inc. · Nov 30, 2007
- Datascope Proguide Chronic Dialysis CatheterK042016 · Datascope Corp. · Sep 23, 2004
- 14.5F X 55CM Hemo-Flow Double Lumen Catheter, Models HFS-55, HFT-55K030502 · Medcomp · May 20, 2003
| Jul 27, 2020 | Z-2940-2020Kits were packaged with the incorrect size valve peelable introducer. The kits include a 15F instead of the correct 16F valve peelable introducer | Terminated |
| Feb 5, 2015 | Z-1351-2015Medcomp has initiated the recall of Duo-Flow 400XL Catheter, Hemo-Flow Catheter, SLX Catheter, Triple Lumen Infusion Catheter, CT rated PICC, Split Cath III, PC Split Cath III because the product shipped was out of… | Terminated |
- End CapK210461 · Medical Components Inc (Medcomp) · Sep 14, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 6, 1999
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5540
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files