Mini 6800 Digital Mobile C-Arm

Image-Intensified Fluoroscopic X-Ray System, Mobile. 510(k) K992506, from Ge Dec Medical Systems (Salt Lake City, UT). Product code OXO, class 2.

As of Nov 20, 2026, K992506 is an FDA 510(k) held by Ge Dec Medical Systems, substantially equivalent on Aug 19, 1999 after 23 days, with 7 recalls tied to it in FDA's recall database.

  • Review time: 23 days
  • Recalls: 7
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The MINI 6800 Digital Mobile C-arm is designed to provide the physician with general fluoroscopic visualization of the patient including but not limited to surgical orthopedic and extremity imaging. The device is not intended for whole-body pediatric imaging.

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K992506, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Dec 19, 2016Z-0974-2017GE Healthcare Surgery announces a voluntary field action for the OEC MiniView 6800, OEC 9900 Elite, and OEC 9800 because the workstation power cable assembly can result in intermittent power cord failures.Terminated
Oct 3, 2014Z-0193-2015GE Healthcare initiated a field correction because prior revision of components were potentially installed on certain OEC 9800, FlexiView 8800, OEC MiniView 6800 and OEC UroView 2800 systems.Terminated
Jun 12, 2007Z-0851-2007X-ray systems were not configured to display Air Kerma Rate and Cumulative Air Kerma.Terminated
May 24, 2007Z-0928-2007X-ray systems did not have the required labeling to indicate Air Kerma Rate and cumulative Air Kerma during fluoroscopic proceduresTerminated
Mar 27, 2007Z-2126-2012Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. GE OEC had discovered an issue with the hard disk drives…Terminated
Nov 20, 2006Z-2040-2012Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. The OEC 6800 Miniview was recalled in November 2006 due to…Terminated
Mar 28, 2006Z-0704-06Radiation exposure rate could exceed specifications during fluoroscopic x-ray procedure.Terminated

Other OXO clearances

The newest 510(k)s for the same product code; their median review was 152 days; see every OXO device

Record

Type
Abbreviated
Received
Jul 27, 1999
Review panel
Radiology
Regulation
21 CFR 892.1650

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files