Intraop Catheter
Pump, Infusion, Elastomeric. 510(k) K991543, from I-Flow Corp. (Lake Forest, CA). Product code MEB, class 2.
As of Nov 18, 2026, K991543 is an FDA 510(k) held by I-Flow Corp., substantially equivalent on Oct 25, 1999 after 175 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 25, 1999
- Review time: 175 days
- Recalls: 0
- Cited as a predicate by: 3 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Intra Op Catheter is intended to provide continuous or intermittent delivery of local anesthetics or narcotics to surgical wound sites and nerve trunks outside of the epidural space. Routes of administration may be either, intraoperative, intramuscular, subcutaneous or percutaneous.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Epidural CatheterK840202 · Aries Medical, Inc. · Feb 27, 1984
- Perfix Set For Epidural Anesthesia W/TuoK813186 · Burron Medical Products, Inc. · Dec 3, 1981
Cited as a Predicate
3 later 510(k) summaries name this device as a predicate- Soaker CatheterK994374 · I-Flow Corp. · Mar 3, 2000
- Spinal Integration Spinal-Eze Intraoperative Epidural Catheter KitK081404 · Spinal Integration, LLC · Oct 21, 2008
- B. Braun Nerve Block CatheterK030830 · B.Braun Medical, Inc. · Jul 15, 2003
Other MEB Clearances
The newest 510(k)s for the same product code; their median review was 245 days; see every MEB device- SMARTeZ™ Elastomeric Infusion Pump (RS series)K250234 · Epic Medical Pte. , Ltd. · Apr 24, 2026
- InfuLifeK240624 · First Medical Source, LLC · Nov 5, 2024
- SMARTeZ™ Elastomeric Infusion Pump (498111, 498121, 498131, 498141)K242152 · Epic Medical Pte. , Ltd. · Oct 7, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 3, 1999
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files