Ad-Tech's Foramen Ovale Electrode
Electrode, Depth. 510(k) K990788, from Ad-Tech Medical Instrument Corp (Racine, WI). Product code GZL, class 2.
As of Nov 19, 2026, K990788 is an FDA 510(k) held by Ad-Tech Medical Instrument Corp, substantially equivalent on Nov 2, 1999 after 237 days, with no recalls tied to it in FDA's recall database.
- Review time: 237 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The foramen ovale electrode is designed for monitoring brain electrical activity (eeg) or defining the location of epileptogenic foci in patients with intractable epilepsy. The foramen ovale electrode is intended for “Surgical Use Only” and “Not Intended for Implantation” This product should only be used by a physician/surgeon trained in the use of foramen ovale electrodes.
- Ad-Tech's Depth ElectrodeK891920 · Ad-Tech Medical Instrument Corp · Jul 27, 1989
- Depth Electrodes, Foramen Ovale Depth Eletrodes, Marco-Micro Depth Electrodes, Spencer Probe Depth ElectrodesK163355 · Ad-Tech Medical Instrument Corporation · Apr 12, 2017
- Depth Electrode, Foramen Ovale Depth Electrodes, Wyler Sphenoidal Depth ElectrodesK053358 · Ad-Tech Medical Instrument Corp · May 25, 2006
- Wovyn Depth ElectrodeK253970 · Sensomedical Labs, Ltd. · Apr 17, 2026
- Depth Electrode (RSDE-08); Depth Electrode (RSDE-10); Depth Electrode (RSDE-12); Depth Electrode (RSDE-14); Depth…K250363 · Beijing Sinovation Medical Technology Co., Ltd. · Nov 5, 2025
- Neuro Omega System; NeuroSmart SystemK250601 · Alpha Omega Engineering , Ltd. · Mar 30, 2025
- Spencer Probe Depth ElectrodesK223269 · Ad-Tech Medical Instrument Corporation · May 18, 2023
- Anchor Bolts as Accessories to Depth ElectrodesK223276 · Ad-Tech Medical Instrument Corporation · May 18, 2023
- SENSOSEEG Depth ElectrodesK213170 · Sensomedical Labs, Ltd. · Apr 18, 2023
- iCE-SG2 Subcutaneous Electrode KitK222706 · Ice Neurosystems, Inc. · Dec 6, 2022
- Evo® sEEG SystemK222404 · Neuroone Medical Technologies Corp. · Oct 20, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 10, 1999
- Review panel
- Neurology
- Regulation
- 21 CFR 882.1330
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files