Release 2 of Philips Integris Series (V5000, BV5000, H5000, BH5000, HM2000) Systems

System, X-Ray, Angiographic. 510(k) K984545, from Philips Medical Systems North America, Inc. (Da Best, NL). Product code IZI, class 2.

As of Nov 19, 2026, K984545 is an FDA 510(k) held by Philips Medical Systems North America, Inc., substantially equivalent on Feb 25, 1999 after 65 days, with 17 recalls tied to it in FDA's recall database.

  • Review time: 65 days
  • Recalls: 17
  • Cited as a predicate by: 7 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Philips Integris Series Release 2 systems are intended for use in acquiring diagnostic quality images during cardiac, angiographic, vascular, neurovascular, and interventional applications.

Cited as a predicate

7 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K984545, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Feb 19, 2019Z-1140-2019, Z-1141-2019Additional units have been identified for previous recall Z-1280-2016 (RES 69339): If a Footswitch is frequently used on a non-flat surface or in the pedestal, the footswitch pedals may get bent. This might cause an…Terminated
Sep 24, 2014Z-1280-2016Loss of key image functionality due to a bent pedal of the Footswitch.Terminated
Oct 7, 2010Z-1655-2011A wire in the connector of the Generator Grid Switch Supervisor box might short-circuit between 12V power and ground, and it will cause a System breakdown.Terminated
Feb 4, 2010Z-2448-2010A lock-up might occur inside the Velara Generator due to intermittent shorts inside the system. The problem could only resolved by a warm or cold system restart. In exceptional cases the power converters of the KVmA…Terminated
Feb 4, 2010Z-2449-2010A lock-up might occur inside the Velara Generator due to intermittent shorts inside the system. The problem can only resolved by a warm or cold system restart. In exceptional cases the power converters of the KVmA unit…Terminated
Dec 10, 2008Z-0344-2009, Z-0346-2009, Z-0345-2009, Z-0348-2009Tube failure occurs involving fluoroscopy of large patients and a partial failure of the grid switch.Terminated
Oct 23, 2008Z-2475-2010, Z-2471-2010, Z-2473-2010, Z-2472-2010A high voltage reliability issue resulting in the loss of the x-ray generation and this can cause an intermittent stop of fluoro acquisition and exposure during an examination without warning and hence no image on the…Terminated
Dec 14, 2006Z-0367-2007Movement of the AD5 table or Lateral C-arm (LARC). The table and/or LARC will not move upon request, will move slowly when movement is requested or will not stop moving when requested.Terminated
Oct 12, 2005Z-0206-06, Z-0207-06Potential for high voltage exposure involving the injector interface connector of patient support tables.Terminated

Other IZI clearances

The newest 510(k)s for the same product code; their median review was 229 days; see every IZI device

Record

Type
Traditional
Received
Dec 22, 1998
Review panel
Radiology
Regulation
21 CFR 892.1600

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.