Skull Base Instatrak System
System, Image Processing, Radiological. 510(k) K982994, from Visualization Technology, Inc. (North Attleboro, MA). Product code LLZ, class 2.
As of Nov 21, 2026, K982994 is an FDA 510(k) held by Visualization Technology, Inc., substantially equivalent on Nov 16, 1998 after 81 days, with 1 recall tied to it in FDA's recall database.
- Review time: 81 days
- Recalls: 1
- Cited as a predicate by: 1 device
The Skull Based InstaTrak System is intended for image guided assistance during skull base surgical procedures. It is intended to be used during skull base surgery involving procedures on the base of the brain (junction of the face and neurocranium).
- InstatrakK960330 · Visualization Technology, Inc. · Apr 8, 1996
- Pediatric Instatrak SystemK981998 · Visualization Technology, Inc. · Aug 21, 1998
- Allegro Viewing WandK911783 · I.S.G. Technologies, Inc. · Apr 7, 1994
- Straight Aspirator, 90 Degree Aspirator,45 Degree Aspirator,7 French Aspirator,Extended Straight Aspirator,13.9 CM StragK990919 · Visualization Technology, Inc. · Apr 15, 1999
| Started | Recall | Status |
|---|---|---|
| Jun 22, 2009 | Z-2251-2012GE Healthcare Surgery had discovered that using the Inverted Headset Placement is not a validated configuration with the IT 3000, 2500, 2500 plus, 3500, 3500 plus, ConneCTstat, and ConneCTstat Plus Surgical Navigation… | Terminated |
- 3D Anatomical ModelK262132 · The Jacobs Institute · Nov 5, 2026
- LiLi DICOM Viewer (LiLi )K260454 · Elevate Imaging, Inc. · Nov 4, 2026
- Vitrea Advanced Visualization, Version 7.16K263648 · Canon Medical Informatics, Inc. · Oct 29, 2026
- MIM – KineticIDK261763 · Mim Software, Inc. · Oct 26, 2026
- PV-iCurve ProK261531 · Perception Vision Medical Technology Co., Ltd. · Oct 21, 2026
- Eden PACSK261788 · Higia., Inc. d/b/a Eden · Oct 21, 2026
- Syngo Carbon Space (VA4)K263048 · Siemens Healthineers AG · Sep 29, 2026
- Syneris PACS v.1.0.1.0K261874 · Syneris · Sep 23, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 27, 1998
- Review panel
- Radiology
- Regulation
- 21 CFR 892.2050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files