Introcan Safety Iv Catheter
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days. 510(k) K982805, from B.Braun Medical, Inc. (Bethlehem, PA). Product code FOZ, class 2.
As of Nov 20, 2026, K982805 is an FDA 510(k) held by B.Braun Medical, Inc., substantially equivalent on Jan 14, 1999 after 157 days, with 1 recall tied to it in FDA's recall database.
- Review time: 157 days
- Recalls: 1
- Cited as a predicate by: 6 devices
A passive anti-needle stick device to be placed in a peripheral vein for the infusion of fluids, large and for blood components
- Burron Microcath Intra. Cath. PlacementtK801941 · Burron Medical Products, Inc. · Aug 27, 1980
- Neo Delta Self Safe T, Neo Delta Self Safe T, Neo Delta Self Safe 1, Neo Delta Self Safe 1K121007 · Delta Med Srl · Dec 28, 2012
- Medican AlphaK063469 · Eastern Medikit , Ltd. · Dec 1, 2006
- Surecan Safety Huber Needle Infusion SetsK021488 · B.Braun Medical, Inc. · Jul 8, 2002
- Introcan Safety Iv CatheterK021094 · B.Braun Medical, Inc. · Jul 3, 2002
- Introcan Safety Iv CatheterK020785 · B.Braun Medical, Inc. · Aug 28, 2002
- Perifix Safety Epidural NeedlesK013610 · B.Braun Medical, Inc. · Jan 25, 2002
| Started | Recall | Status |
|---|---|---|
| Mar 19, 2004 | Z-1092-04Mislabeled product. The recalling firm received a complaint that a box of Introcan Safety Catheters, (22G x 1 inch) contained mixed 18G catheters with the same lot number. | Terminated |
- Medican Alpha, Medican, Mediflon, Mediflon Quick, Medican Alpha Safety, Medican Safety, Mediflon Safety, Mediflon…K260631 · Global Medikit Limited · Nov 5, 2026
- Ruby Intravascular CatheterK260432 · Venocare, Inc. · Sep 2, 2026
- Unimpregnated Central Venous CatheterK260165 · Spectrum Vascular · Aug 10, 2026
- ClearSafe Closed SystemK261041 · MedSource Labs, LLC · Jul 10, 2026
- MedSource QuickSafe™ Safety IV Catheter; MedSource PurSafe™ Safety IV CatheterK260539 · MedSource Labs, LLC · Jul 9, 2026
- Introcan Safety® Deep Access XL IV CatheterK253235 · B.Braun Medical, Inc. · May 15, 2026
- BD Insyte™ IV CatheterK252137 · Becton Dickinson Infusion Therapy Systems, Inc. · Apr 2, 2026
- Polywin Safety (14G x 51mm; 16G x 51mm; 18G x 64mm; 20G x 64mm; 20G x 45mm; 22G x 64mm; 22G x 45mm; 24G x 32mm; 24G x…K252513 · Poly Medicure Limited · Apr 1, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 10, 1998
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5200
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files