Power-Drive, Wisap Model #7688PD/7688PD1
Laparoscope, Gynecologic (And Accessories). 510(k) K982515, from Wisap Gesellschaft Fur Wissenschaftl. App. Bau Mbh (Sauerlach, DE). Product code HET, class 2.
As of Nov 27, 2026, K982515 is an FDA 510(k) held by Wisap Gesellschaft Fur Wissenschaftl. App. Bau Mbh, substantially equivalent on Jan 19, 1999 after 183 days, with no recalls tied to it in FDA's recall database.
- Review time: 183 days
- Recalls: 0
- Cited as a predicate by: 1 device
This device is restricted to use by authorized expert personnel/physicians. The WISAP POWER-DRIVE is a laparoscopic accessory to be used in connection with the S*E*M*M*-Set. It allows cutting of tissue cylinders out of myoma and uteri by continuous rotation of the motor drive or additional intermittent manual rotation. The POWER-DRIVE may only be used for horizontal morcellation.
- Morce Power Plus and Variocarve MorcellatorK080365 · Nouvag AG · Jun 29, 2009
- SIRIUS Endoscope System (PR-SI-1230)K250939 · Precision Robotics (Hong Kong) Limited · Aug 29, 2025
- i-CutK243821 · A.M.I. Agency For Medical Innovations GmbH · Apr 25, 2025
- SIRIUS Endoscope SystemK221642 · Precision Robotics (Hong Kong) Limited · Dec 12, 2022
- Video Endoscopy System, 3D Video Endoscopy SystemK210116 · Surgnova Healthcare Technologies (Zhejiang) Co., Ltd. · Oct 13, 2021
- Endoeye Flex Deflectable Videoscope Olympus LTF-S190-5K201832 · Olympus Medical Systems Corp. · Sep 17, 2021
- SurroundScope SystemK210104 · 270surgical , Ltd. · Jul 8, 2021
- TipVision Videoscope System (TipVision VideoScope 0°/30°; EleVision HD 2 Camera Control Unit (CCU))K201617 · Schoelly Fiberoptic GmbH · Mar 12, 2021
- Type
- Traditional
- Received
- Jul 20, 1998
- Review panel
- Obstetrics/Gynecology
- Regulation
- 21 CFR 884.1720
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files