Dura-Guard - Dural Repair Patch
Dura Substitute. 510(k) K982282, from Bio-Vascular, Inc. (St. Paul, MN). Product code GXQ, class 2.
As of Nov 21, 2026, K982282 is an FDA 510(k) held by Bio-Vascular, Inc., substantially equivalent on Jul 30, 1998 after 30 days, with 1 recall tied to it in FDA's recall database.
- Review time: 30 days
- Recalls: 1
- Cited as a predicate by: 4 devices
For use as a dural substitute for the closure of dura mater during neurosurgery.
- Dura-Guard-Dural Repair PatchK973706 · Bio-Vascular, Inc. · Dec 24, 1997
- Bovine Pericardium Suturable Dural Graft, Tutopatch DM Graft, Tutoplast Bovine Pericardium DMK132850 · Rti Surgical, Inc. · Mar 31, 2014
- Synthecel Dura Replacement DevicesK113071 · Synthes · Jan 9, 2012
- Lifecell Dural Substitute MatrixK061208 · Lifecell Corp. · Jan 3, 2007
- Durepair Dura Regeneration MatrixK041000 · Medtronic Neurosurgery · Jul 27, 2004
| Started | Recall | Status |
|---|---|---|
| Oct 28, 2013 | Z-0339-2014Synovis, a subsidiary of Baxter International Inc., is recalling certain shipments of VASCUGUARD and DURA-GUARD because Synovis, a subsidiary of Baxter International Inc., is recalling certain shipments of VASCUGUARD… | Terminated |
- Dura-Guard Dural Repair PatchK260431 · Synovis Life Technologies, Inc. (Baxter International Inc.) · Nov 5, 2026
- Collagen Dura Regeneration Membrane - RepairK251191 · Collagen Matrix, Inc. · Nov 18, 2025
- Helios Dura Regeneration MatrixK250420 · Helios Biomedical, Inc. · May 14, 2025
- ArtiFasciaK223445 · Nurami Medical , Ltd. · Aug 10, 2023
- SyntheCel Dura RepairK212943 · Synthes (USA) Products, LLC · Jan 28, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 30, 1998
- Review panel
- Neurology
- Regulation
- 21 CFR 882.5910
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files