Arca
Skip to content
Tools
Tools

Olympus AU400 Clinical Chemistry Analyzer

Acid Phosphatase, Naphthyl Phosphate. 510(k) K981743, from Olympus America, Inc. (Melville, NY). Product code CKB, class 2.

As of Nov 18, 2026, K981743 is an FDA 510(k) held by Olympus America, Inc., substantially equivalent on Jun 9, 1998 after 22 days, with 5 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Jun 9, 1998
  • Review time: 22 days
  • Recalls: 5
  • Cited as a predicate by: 2 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

Photometric clinical chemistry analyzer for clinical laboratory use. Applications include colorimtric, turbidimetric, latex agglutination and homogenous enzyme immunoassay.

Cited as a Predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K981743, newest first; each opens FDA's recall record
Aug 3, 2026Z-3332-2026Certain AU480 chemistry analyzers, with Windows 10 IoT Enterprise 2021 LTSC PCs, may output the message System Stopped By Fatal Error: DBConnectionError AlarmDB when launching the instrument software, using PC…Open, Classified
Apr 30, 2025Z-1907-2025A manufacturing defect in the sample probe (S probe). The corners of the tip of the defective S probe are rounded and chamfered, which can prevent the proper formation of the "air layer" required for normal dispensing.…Completed
Sep 9, 2013Z-0153-2014The recall was initiated because Beckman Coulter has confirmed that some AU Clinical Chemistry Analyzer ISE units can experience premature ISE REF (Reference) valve failure. Premature valve failure can be detected by…Terminated
Sep 9, 2013Z-0152-2014The recall was initiated because Beckman Coulter has confirmed that some AU Clinical Chemistry Analyzer ISE units can experience premature ISE REF (Reference) valve failure. Premature valve failure can be detected by…Terminated
Jul 12, 2010Z-0974-2012The recall was initiated because Beckman has confirmed that the AU Clinical Chemistry Analyzers may experience cuvette overflow.Terminated

Record

Type
Special
Received
May 18, 1998
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1020

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.