Bci 3401 Handheld Pulse Oximeter
Oximeter. 510(k) K980714, from Bci Intl., Inc. (Waukesha, WI). Product code DQA, class 2.
As of Nov 19, 2026, K980714 is an FDA 510(k) held by Bci Intl., Inc., substantially equivalent on Mar 25, 1998 after 29 days, with no recalls tied to it in FDA's recall database.
- Review time: 29 days
- Recalls: 0
- Cited as a predicate by: 3 devices
Intended Use The BCI 3401 Pulse Oximeter is a handheld, low cost monitor for spot checking or attended monitoring of $SpO_{2}$, pulse rate and pulse strength. The 3401 is a battery powered pulse oximeter with an optional built-in printer. It may be used in the hospital or clinical environment, and during emergency land.
- 3402 Handheld Pulse OximeterK991410 · Bci Intl., Inc. · Jun 9, 1999
- Bci 3180 Pulse OximeterK020350 · Bci, Inc. · Apr 30, 2002
- 3420 Digit Pulse Oximeter, Model 3420K013171 · Bci, Inc. · Jan 3, 2002
- ANNE LimbK261870 · Sibel Health · Nov 5, 2026
- Ninenovo Blood Oxygen Ring…K260490 · Shenzhen Ninenovo Technology Limited · Oct 2, 2026
- Reusable Adult SpO2 Clip Sensor (3m) (M1196A); Reusable Adult SpO2 Clip Sensor (0.9m) (M1196T)K252821 · Philips Medizin Systeme Böblingen GmbH · May 29, 2026
- Pulse Oximeter (PO-A2AO, PO-A2AT, PO-A3AO, PO-H1AO, PO-B1AO, PO-C5AO, PO-C5AT, PO-C6AO, PO-C6AT)K252655 · Shenzhen Imdk Medical Technology Co., Ltd. · May 11, 2026
- Nasal Alar SpO2 Sensor (989803205381); Nasal Alar SpO2 Sensor (989803205391); Nasal Alar Sp02 Sensor (989803205401)K253887 · Philips Medizin Systeme · May 1, 2026
- Unimed Reusable Finger Clip SpO2 Sensors (U403-49R and U103-49R)K260931 · Unimed Medical Supplies, Inc. · Apr 14, 2026
- AViTA Pulse Oximeter (SP61)K252448 · Avita Corporation · Feb 27, 2026
- YUWELL® Finger Pulse Oximeter (YX105, YX106, YX110, YX310)K252805 · Jiangsu Yuyue Medical Equipment & Supply Co., Ltd. · Feb 17, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 24, 1998
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2700
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files