Olympus TJF-140R/JF-140R Evis Duodenovideoscopes and Accessories, Olympus MAJ-311/MAJ-411 Distal Covers
Duodenoscope And Accessories, Flexible/Rigid. 510(k) K980465, from Olympus America, Inc. (Melville, NY). Product code FDT, class 2.
As of Nov 18, 2026, K980465 is an FDA 510(k) held by Olympus America, Inc., substantially equivalent on Apr 21, 1998 after 75 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 75 days
- Recalls: 2
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFTJF-140R/JF-140R Duodenovideooscopes Olympus TJF-140R/JF-140R Duodenovideooscopes have been designed to be used with an Olympus EVIS Video System Center, light source, documentation equipment, video monitor, Endo-Therapy Accessories (Forceps, Brush, Electrosurgical Accessories, etc.), Electrosurgical Unit, and other Ancillary Equipment for endoscopy and endoscopic surgery within the duodenum.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Evis 140 SystemK954451 · Olympus America, Inc. · Mar 29, 1996
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- FUJIFILM Endoscope Model ED-S100TP; FUJIFILM Endoscope Model ED-S100XP; FUJIFILM Processor Model VS-1000K251861 · Fujifilm Corporation · Mar 9, 2026
- XTJF-160AF DuodenovideoscopeK024033 · Olympus Optical Co., Ltd. · Dec 20, 2002
Recalls
Recalls FDA ties to K980465, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Started | Recall | Status |
|---|---|---|
| Sep 25, 2023 | Z-0341-2024, Z-0342-2024Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for… | Open |
Other FDT clearances
The newest 510(k)s for the same product code; their median review was 94 days; see every FDT device- FUJIFILM Endoscope Model ED-S100TP; FUJIFILM Endoscope Model ED-S100XP; FUJIFILM Processor Model VS-1000K251861 · Fujifilm Corporation · Mar 9, 2026
- Single Use Distal Cover MAJ-2315 (MAJ-2315)K253646 · Olympus Medical Systems Corp. · Feb 22, 2026
- Evis Exera Iii Duodenovideoscope Olympus TJF-Q190V (TJF-Q190V)K251867 · Olympus Medical Systems Corp. · Sep 19, 2025
- Evis Exera III Duodenovideoscope Olympus TJF-Q190V (TJF-Q190V)K250701 · Olympus Medical Systems Corp. · Jun 5, 2025
- PENTAX Medical Video Duodenoscope (ED34-i10T2s); PENTAX Medical Video Processor (EPK-i8020c); PENTAX Medical Single…K233942 · Pentax of America, Inc. · Aug 1, 2024
- Ambu® aScope™ Duodeno 2, Ambu® aBox™ 2K233886 · Ambu A/S · Apr 16, 2024
- Evis Exera III Duodenovideoscope Olympus TJF-Q190VK220587 · Olympus Medical Systems Corp. · May 11, 2022
- PENTAX Medical Video Duedenoscope ED34-i10T2K210710 · Pentax of America, Inc. · Apr 9, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 5, 1998
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.1500
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files