Schneider Guider Softip Guiding Catheters

Catheter, Percutaneous. 510(k) K980453, from Boston Scientific Scimed, Inc. (Plymouth, MN). Product code DQY, class 2.

As of Nov 23, 2026, K980453 is an FDA 510(k) held by Boston Scientific Scimed, Inc., substantially equivalent on Aug 11, 1998 after 187 days, with 20 recalls tied to it in FDA's recall database.

  • Review time: 187 days
  • Recalls: 20
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The SCHNEIDER GUIDER Softip® Guiding Catheters are designed for the introduction of interventional devices. They are intended to facilitate the placement of interventional devices into the peripheral and coronary systems and, in addition for the XF models, into the neurovascular system.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K980453, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 9, 2022Z-1582-2022The impacted products were distributed with an MPXF tip curve shape instead of the 40XF tip curve shape for the Guider/40XF/8FR/90CM guide catheter.Open
Dec 11, 2017Z-2735-2018Potential polymer material degradation.Terminated
Oct 5, 2016Z-0335-2017, Z-0345-2017, Z-0343-2017, Z-0336-2017, Z-0344-2017, Z-0346-2017, Z-0347-2017, Z-0342-2017, Z-0334-2017, Z-0340-2017, Z-0337-2017, Z-0341-2017, Z-0333-2017, Z-0339-2017, Z-0338-2017Firm became aware of potentially defective Guider Guide Catheters due to a manufacturing non-conformance that could lead to hub leaks in the resulting product.Terminated
Oct 6, 2009Z-0107-2010Product degradation-- a polymer portion of the distal section of the catheter may degrade prematurely, leading to potential systemic embolization of particulates with ischemic complications.Terminated
Jul 11, 2007Z-0260-2008Mislabeling: Catheters were found to be mislabeled (100 cm labeled devices actually contains 90cm length catheter)Terminated
Jul 11, 2007Z-0259-2008Mislabeling: Catheters were found to be mislabeled (90 cm labeled devices actually contains 100 cm length catheter)Terminated

Other DQY clearances

The newest 510(k)s for the same product code; their median review was 42 days; see every DQY device

Record

Type
Traditional
Received
Feb 5, 1998
Review panel
Cardiovascular
Regulation
21 CFR 870.1250

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files