Osteonics Polyethylene Acetabular Components
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented. 510(k) K974685, from Osteonics Corp. (Allendale, NJ). Product code JDI, class 2.
As of Nov 17, 2026, K974685 is an FDA 510(k) held by Osteonics Corp., substantially equivalent on Sep 22, 1998 after 280 days, with 1 recall tied to it in FDA's recall database.
- Substantially equivalent: Sep 22, 1998
- Review time: 280 days
- Recalls: 1
- Cited as a predicate by: 4 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFOsteonics® Crossfire™ Polyethylene Acetabular Components are single use components, intended for use in conjunction with an associated Osteonics® metal acetabular shell, femoral bearing, and femoral hip stem, as part of a cemented or cementless total hip arthroplasty.
Cited as a Predicate
4 later 510(k) summaries name this device as a predicate- Crossfire System 12 Acetabular InsertsK993352 · Howmedica Osteonics Corp. · Nov 19, 1999
- Omnifit® 20° Series I Insert;Omnifit® Crossfire® 10° Series II Insert; Constrained…K261624 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Jul 10, 2026
- Stryker Orthopaedics Hip Devices Labeling UpdateK243784 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Feb 6, 2025
- Modified Bencox Hip SystemK150007 · Corentec Co., Ltd. · May 4, 2015
Recalls
Recalls FDA ties to K974685, newest first; each opens FDA's recall record| Started | Reason | Status |
|---|---|---|
| Nov 7, 2019 | Z-0811-2020May have a missing locking wire causing delay in surgery while retrieving a back-up device or implantation of a device that is missing a locking wire | Terminated |
Other JDI Clearances
The newest 510(k)s for the same product code; their median review was 219 days; see every JDI device- Libertas Acetabular Liners (Acetabular Liner)K260975 · Maxx Orthopedics, Inc. · Oct 29, 2026
- Zimmer Biomet OSS Orthopedic Salvage System OsseoTi® Sleeves and AugmentsK253515 · Biomet Orthopedics, Inc. · Aug 24, 2026
- OSSTM Orthopedic Salvage SystemK253434 · Biomet, Inc. · Jul 1, 2026
- Evolve AP Cup, World Finned Cup, World G-Zero Liner and Oddball Femoral HeadK252824 · Signature Orthopaedics Pty, Ltd. · Mar 12, 2026
- Trabecular Metal Acetabular Revision System, Acetabular Liners and Constrained LinersK243571 · Zimmer Biomet · Jul 31, 2025
- Anthology Hip Stems; CPCS Hip Stems; Femoral Heads; R3 Acetabular Liners; Spectron Hip…K240783 · Smith & Nephew, Inc. · Oct 21, 2024
- Global Modular Replacement System, Modular Replacement System, Modular Rotating Hinge…K241716 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Aug 2, 2024
- Stryker Orthopaedics Hip Systems Labeling UpdateK240418 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Apr 12, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 16, 1997
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3350
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files