Airis Ii
System, Nuclear Magnetic Resonance Imaging. 510(k) K974212, from Hitachi Medical Systems America, Inc. (Twinsburg, OH). Product code LNH, class 2.
As of Nov 19, 2026, K974212 is an FDA 510(k) held by Hitachi Medical Systems America, Inc., substantially equivalent on Feb 9, 1998 after 91 days, with 5 recalls tied to it in FDA's recall database.
- Review time: 91 days
- Recalls: 5
- Cited as a predicate by: 10 devices
The MR system is an imaging device, and is intended to provide the physician with physiological and clinical information, obtained non-invasively and without the use of ionizing radiation. The MR system produces transverse, coronal, sagittal, oblique, and curved cross-sectional images that display the internal structure of the head, body, or extremities.
- Airis IiK994378 · Hitachi Medical Systems America, Inc. · Mar 7, 2000
- Virgo Mri SystemK990153 · Millennium Technology Services · Oct 8, 1999
- Airis Ii Magnetic Resonance Diagnostic Device,Interventional Mr PackageK984280 · Hitachi Medical Systems America, Inc. · Feb 8, 1999
- Magnetic Resonance Diagnostic Device, Airis IiK984278 · Hitachi Medical Systems America, Inc. · Dec 11, 1998
- Oper Series Open Type Permanent-Magnet Mri System, Model: OPER-0.3, -0.35, -0.4K092899 · Ningbo Xingaoyi Magnetism Co., Ltd. · Nov 10, 2009
- I Open 0.5TK090873 · Beijing Wandong Medical Equipment Co., Ltd. · Apr 10, 2009
- I_Open 0.4TK090433 · Beijing Wandong Medical Equipment Co., Ltd. · Mar 25, 2009
- Cirrus OpenK090080 · Mri-Tech Sp. Zo.O. · Mar 23, 2009
- Airis Elite Magnetic Resonance Imaging DeviceK032232 · Hitachi Medical Systems America, Inc. · Sep 29, 2003
- Superopen 0.35T, Model NSM-P035K030918 · Neusoft Digital Medical Systems Co., Ltd. · Apr 1, 2003
| Apr 28, 2006 | Z-1104-06Software anomaly-A software defect can cause the slice line indicator to become mis-positioned during Multi-Planar Reconstructions (MPR) with the potential for patient mis-diagnosis. | Terminated |
| Apr 25, 2006 | Z-1115-06Improper Assembly-The AIRIS/AIRIS II MRI system has the potential for the input wiring of a power transformer to overheat due to damaged wiring or possible loose connections. | Terminated |
| Feb 21, 2006 | Z-0910-06The device has a software anomaly which causes the operating system to 'lock up' and data to become corrupted during service procedures. | Terminated |
| Dec 1, 2005 | Z-0429-06The bolts holding the lift mechanism may be damaged causing them to fail and the table top to drop several inches. | Terminated |
| Jun 30, 2005 | Z-0889-05Image reconstruction software problem that could potentially cause multiple patient images to be stored in one patient folder. | Terminated |
- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 10, 1997
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files