Versys Hip System Beaded Hip Prosthesis
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented. 510(k) K973714, from Zimmer, Inc. (Warsaw, IN). Product code LPH, class 2.
As of Nov 19, 2026, K973714 is an FDA 510(k) held by Zimmer, Inc., substantially equivalent on Dec 24, 1997 after 86 days, with 8 recalls tied to it in FDA's recall database.
- Review time: 86 days
- Recalls: 8
- Cited as a predicate by: 3 devices
The VerSys Beaded Hip Prosthesis is designed to achieve biologic fixation to bone and is indicated for: Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur, congenital hip dysplasia, protrusio…
- Beta Hip ProsthesisK953337 · Zimmer, Inc. · Jan 22, 1996
- P820024P820024
- Porocoat Porous CoatingK931641 · Depuy, Inc. · Mar 21, 1994
- Zimmer M/L Taper Hip ProsthesisK060040 · Zimmer, Inc. · May 12, 2006
- Versys Hip System Beaded Midcoat Low Head Center Hip Prosthesis, Model 00-7840-XXX-XXK042776 · Zimmer, Inc. · Nov 4, 2004
- Versys Beaded Fullcoat Bowed Revision Hip ProsthesisK030079 · Zimmer, Inc. · Feb 5, 2003
| Nov 29, 2017 | Z-1024-2018, Z-1023-2018, Z-1025-2018, Z-1026-2018, Z-1022-2018The LDPE bag packaging for various highly polished hip and knee implants may adhere to the highly polished surface, leaving residue or material from the LDPE bag on the implant after it is removed from the bag. | Terminated |
| Aug 1, 2017 | Z-0722-2018The products being recalled exceeded the weight previously tested leading to a possibility of damage to the package and/or a compromised sterile barrier. | Terminated |
| Jan 11, 2016 | Z-0848-2016LDPE bag containing the implant adheres to the highly polished implant surface. | Terminated |
| May 19, 2014 | Z-1842-2014During routine inspection, beaded hip stem forgings received from supplier failed to meet ZES 2A-102. Processing of Beaded CoCrMo Alloy Hip Stem, material requirements per ATS #14-04818 and ATS #14-05549, respectively. | Terminated |
- G7® Acetabular SystemK261453 · Zimmer Biomet · Sep 23, 2026
- Mpact 3D Metal FoamK253630 · Medacta International S.A. · Aug 28, 2026
- TRIVANCE™ Hip StemK254043 · Globus Medical, Inc. · Aug 4, 2026
- Omnifit® 20° Series I Insert;Omnifit® Crossfire® 10° Series II Insert; Constrained Acetabular Insert; Trident®…K261624 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Jul 10, 2026
- iNSitu Lateralized Acetabular Liners, iNSitu Femoral Stems with Plasma Sprayed CPTi CoatingK243192 · Nextstep Arthopedix, LLC · Jun 5, 2026
- Taperloc® Complete Hip StemK251270 · Biomet, Inc. · May 19, 2026
- G7® Revision Acetabular SystemK252623 · Zimmer, Inc. · Feb 4, 2026
- Mpact 3D Metal Implants Extension – DMLS TechnologyK251043 · Medacta International S.A. · Jan 28, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 29, 1997
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3358
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files