Hermes Operating Room Control Center
Laparoscope, General & Plastic Surgery. 510(k) K973700, from Computer Motion, Inc. (Goleta, CA). Product code GCJ, class 2.
As of Nov 17, 2026, K973700 is an FDA 510(k) held by Computer Motion, Inc., substantially equivalent on Feb 24, 1998 after 151 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Feb 24, 1998
- Review time: 151 days
- Recalls: 0
- Cited as a predicate by: 9 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDF4. Indications For Use The HERMES OR Control Center is indicated for use with Stryker Endoscopy 882 Camera and Quantum 5000 Light Source that is used in general laparoscopy, nasopharyngoscopy, ear endoscopy, and sinuscopy where a laparoscope/endoscope is indicated for use.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Aesop (Automated Endoscopic System For Optimal PosK931783 · Computer Motion, Inc. · Nov 22, 1993
- Aesop System And AccessoriesK960655 · Computer Motion, Inc. · May 3, 1996
- Syn-Optics #5200K820624 · Syn-Optics · Apr 1, 1982
- Q-5000K961971 · Stryker Endoscopy · Jun 28, 1996
Cited as a Predicate
9 later 510(k) summaries name this device as a predicate- Stryker Hermes-Ready Total Performance SystemK991696 · Stryker Instruments · Oct 25, 1999
- Hermes Operating Room Control Center With The Wom 20L InsufflatorK980787 · Computer Motion, Inc. · Jul 13, 1998
- Modification To Hermes O.R. Control CenterK031956 · Computer Motion, Inc. · Jul 17, 2003
- Modification To Hermes O.R. Control CenterK031720 · Computer Motion, Inc. · Jul 11, 2003
- Modification To Hermes O.R. Control CenterK031382 · Computer Motion, Inc. · Jun 30, 2003
- Modification To Hermes Operating Room Control CenterK030240 · Computer Motion, Inc. · Feb 21, 2003
- Modification To Hermes Operating Room Control CenterK024294 · Computer Motion, Inc. · Jan 8, 2003
- Hermes Operating Room Control CenterK023095 · Computer Motion, Inc. · Nov 15, 2002
- Modification To Hermes Operating Room Control CenterK022897 · Computer Motion, Inc. · Oct 11, 2002
Other GCJ Clearances
The newest 510(k)s for the same product code; their median review was 128 days; see every GCJ device- SwicsK263459 · Bloom Surgical, Inc. · Oct 29, 2026
- da Vinci 5 Handheld Camera Head (470080);da Vinci 5 Handheld Camera Laparoscope, 0 degree…K262455 · Intuitive Surgical, Inc. · Oct 14, 2026
- CuratOR EX2742K262397 · Eizo Corporation · Sep 11, 2026
- UNIDRIVE Select SystemK260884 · Karl Storz SE & CO. KG · Sep 1, 2026
- OEV-271MUH LCD Monitor;OEV-321MUH LCD Monitor;OEV-431MUH LCD MonitorK260972 · Sony Corporation · Aug 26, 2026
- VereSee (VER150, VER200, VER151, VER201, VER200C, and VER-100-103)K261139 · Freyja Healthcare, LLC · Aug 13, 2026
- EZ-Close (EZ Close Port Site Closing Device, EZ Close MAX Port Site Closing Device, EZ…K253541 · Medical Impact · Jul 24, 2026
- LED LCD Monitor (OEV-271H)K261614 · Lg Electronics.Inc · Jul 17, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 26, 1997
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.1500
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files