Auto Suture*Endostitch* Ii** Suture Applier
Suture, Nonabsorbable, Synthetic, Polyethylene. 510(k) K972911, from United States Surgical, A Division of Tyco Healthc (Norwalk, CT). Product code GAT, class 2.
As of Nov 19, 2026, K972911 is an FDA 510(k) held by United States Surgical, A Division of Tyco Healthc, substantially equivalent on Apr 25, 1998 after 261 days, with no recalls tied to it in FDA's recall database.
- Review time: 261 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The Auto Suture* SurgiStitch** suture passer is indicated for the placement of interrupted sutures for soft tissue approximation in surgical procedures such as cardiovascular and gastrointestinal surgery.
- 1.2MM Reusable Neuroview EndoscopeK961173 · Neuro Navigational Corp. · Jun 7, 1996
- Overstitch Endoscopic Suture SystemK081853 · Apollo Endosurgery, Inc. · Aug 18, 2008
- Anchor Band Suturing System, Model Sr-ABK061386 · Anulex Technologies, Inc. · Jul 5, 2006
- Lifestitch Suturing DeviceK013990 · Edwards Lifesciences, LLC · Feb 27, 2002
- Stitch - Suture Wires and TapesK253910 · GM Dos Reis Industria e Comercio Ltda. · Aug 22, 2026
- EasyWhip FamilyK261021 · Winter Innovations, Inc. · Jul 1, 2026
- Polyethylene;Polyethylene Fusion;Polyethylene OrthoTape™K260775 · Teleflex Medical, LLC · May 6, 2026
- HyperSuture All Green Extension LineK254275 · Threadstone, LLC · Mar 23, 2026
- Meniscus VersaflexK254188 · GM Dos Reis Industria e Comercio Ltda. · Feb 19, 2026
- Pre-Sutured TendonK253145 · Rti Surgical, Inc. · Oct 22, 2025
- ProZip Knotless ImplantK253024 · Riverpoint Medical · Oct 16, 2025
- PowerKnot High Strength SuturesK252225 · Medacta International S.A. · Sep 12, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 7, 1997
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.5000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files