Emg Retrainer
Device, Biofeedback. 510(k) K972487, from Chattanooga Group, Inc. (Hixson, TN). Product code HCC, class 2.
As of Nov 18, 2026, K972487 is an FDA 510(k) held by Chattanooga Group, Inc., substantially equivalent on Sep 26, 1997 after 86 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Sep 26, 1997
- Review time: 86 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDF1. To determine the activation timing of muscles. a) retraining of muscle activation b) coordination of muscle activation 2. An indication of the force produced by muscle a) control and maintenance of muscle contractions 3. For use in relaxation training and muscle re-education.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Thaisan Gloves (Patient Exam Gloves - Latex)K891732 · Thaisan Industries Co., Ltd. · Apr 26, 1989
- Verimed Myoexorciser Iii (Myo Iii)K892649 · Verimed Holdings, Inc. · Dec 13, 1989
- MYOTRAC2K915858 · Thought Technology , Ltd. · Sep 9, 1992
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- Lorenz Biotech Aptiva, Version 2.13K061828 · Lorenz Biotech S.P.A. · Aug 24, 2007
- Triton/Tru-Trac/Tx/Triton Dts TractionK053223 · Chattanooga Group · Feb 24, 2006
Other HCC Clearances
The newest 510(k)s for the same product code; their median review was 268 days; see every HCC device- AesyBite ActiveK260360 · Aesyra SA · Oct 30, 2026
- A Breathing System (ABS)K233580 · Deepwell Dtx, Inc. · Aug 1, 2024
- PrismK222101 · Graymatters Health , Ltd. · Mar 17, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 2, 1997
- Review panel
- Neurology
- Regulation
- 21 CFR 882.5050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files