Laparotomy Bladder Neck Suspension Kit With Bone Anchors
Catheter, Retention Type, Balloon. 510(k) K971796, from Louisville Laboratories, Inc. (North Attleboro, MA). Product code EZL, class 2.
As of Nov 19, 2026, K971796 is an FDA 510(k) held by Louisville Laboratories, Inc., substantially equivalent on Aug 12, 1997 after 89 days, with no recalls tied to it in FDA's recall database.
- Review time: 89 days
- Recalls: 0
- Cited as a predicate by: 1 device
The Louisville Laboratories, Inc. Laparotomy Bladder Neck Suspension Kit With Bone Anchors is indicated for urethropexy procedures for bladder neck suspension to correct female stress incontinence due to urethral hypermobility.
- Laparoscopic Bone Anchored Urethropexy Instrument TrayK963076 · Louisville Laboratories, Inc. · Apr 4, 1997
- Vesitec Suture PasserK931181 · Vesitec Medical, Inc. · May 12, 1993
- Vesitec Drill GuideK931182 · Vesitec Medical, Inc. · Jun 9, 1993
- Bone Anchor for Soft Tissue AttachmentK932925 · Vesitec Medical, Inc. · Apr 26, 1994
- Urethropexy Suture Placement Kit Model Numbers UM-300, MW-100, Mini-Laparotomy Mmk Kit Model UM-250, Laparoscopic Burch0K982626 · Medworks Corp. · Aug 20, 1998
- OpenFlo Urinary CatheterK261141 · Urolution Medical, Inc. · Oct 6, 2026
- TraumaGuard Intra-Abdominal Pressure-Sensing System (000-0221)K260756 · Sentinel Medical Technologies, · Sep 4, 2026
- Rusch Latex Gold Foley CatheterK262056 · Teleflex Medical Sdn. Bhd. · Aug 5, 2026
- Rusch SoftSimplastic Foley CathetersK252537 · Teleflex Medical Sdn. Bhd. · Jan 20, 2026
- Silicone Urethral Catheter (Silicone Urethral Catheter)K243011 · Guangdong Ecan Medical Co., Ltd. · Jun 16, 2025
- InnoCare Specialty Foley CatheterK241424 · Innocare Urologics, LLC · Sep 18, 2024
- Rüsch Latex Gold Foley CatheterK232469 · Teleflexmedical, Inc. · Aug 1, 2024
- TraumaGuard Intra-abdominal Pressure Sensing SystemK240057 · Sentinel Medical Technologies, LLC · Apr 17, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 15, 1997
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5130
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files