Arca
Skip to content
Tools
Tools

Snt Disposable Biopsy Needle

Neurological Stereotaxic Instrument. 510(k) K971247, from Surgical Navigation Technologies, Inc. (Broomfield, CO). Product code HAW, class 2.

As of Nov 21, 2026, K971247 is an FDA 510(k) held by Surgical Navigation Technologies, Inc., substantially equivalent on Jun 16, 1997 after 74 days, with 6 recalls tied to it in FDA's recall database.

  • Review time: 74 days
  • Recalls: 6
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

黄 The SNT DISPOSABLE BIOPSY NEEDLE is intended to be used for stereotaxic biopsy of brain tissue. This needle is only intended for use with the StealthStation™ Image Guided Surgery System and it's rigid needle guide holder. The biopsy needle is supplied sterile and is intended for single use only.

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K971247, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 31, 2026Z-0197-2027Sterile Passive spheres and biopsy needle kits contain variation in the reflective material which may affect the ability of the navigation system to detect and track the spheres.Open
Oct 30, 2019Z-0657-2020, Z-0658-2020, Z-0659-2020The firm has become aware that due to a manufacturing issue impacting the biopsy needle depth stop, there exist the potential that some biopsy needle depth stops, when tightened, may not securely tighten to the biopsy…Open
Jul 17, 2015Z-2324-2015, Z-2325-2015The adhesive between the sphere assembly and the biopsy needle shaft may be compromised, causing the sphere assembly to move on the needle shaft. This may result in inaccurate navigation and improper placement of the…Terminated

Other HAW clearances

The newest 510(k)s for the same product code; their median review was 162 days; see every HAW device

Record

Type
Traditional
Received
Apr 3, 1997
Review panel
Neurology
Regulation
21 CFR 882.4560

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files