Multitak Ss Suture System
Fastener, Fixation, Nondegradable, Soft Tissue. 510(k) K971144, from Bonutti Research (Effingham, IL). Product code MBI, class 2.
As of Nov 17, 2026, K971144 is an FDA 510(k) held by Bonutti Research, substantially equivalent on Jun 25, 1997 after 89 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jun 25, 1997
- Review time: 89 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Multitak Suture System is intended for soft tissue to bone suture fixation for the following indications: Shoulder Knee Bankart lesion repairs Extra-capsular repairs: S.L.A.P. lesion repairs Medial collateral ligament Acromio-clavicular repairs Lateral collateral ligament Capsular shift/capsulolabral reconstruction Posterior oblique ligament Deloid repair Iliotibial band tenodesis Rotator…
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Bonutti AnchorK934183 · Apogee Medical Products, Inc. · Apr 3, 1996
- Mitek Gii AnchorK953877 · Mitek Surgical Products, Inc. · Dec 29, 1995
- Mitek Mini Anchor, ModificationK930892 · Mitek Surgical Products, Inc. · Jan 7, 1994
- Quickanchor (Tm)K904436 · Mitek Surgical Products, Inc. · Dec 11, 1990
- Statak & Mini-Statak Soft Tissue Attachment DeviceK926384 · Zimmer, Inc. · Nov 16, 1993
Other MBI Clearances
The newest 510(k)s for the same product code; their median review was 30 days; see every MBI device- Arthrex FiberButtonK263477 · Arthrex, Inc. · Oct 27, 2026
- Q-FIX KNOTLESS All-Suture Anchor, 1.8mm, with one ULTRABRAID Suture, Blue; Q-FIX KNOTLESS…K263348 · Smith & Nephew, Inc. · Oct 23, 2026
- TeKBrace Knotless AnchorK263352 · TheraMicro · Oct 21, 2026
- Integrity Retractable Implant Inserter (6000127)K261869 · Anika Therapeutics, Inc. · Sep 17, 2026
- Aevumed SUPERCYNCH Button SystemK253065 · Aevumed, Inc. · Sep 2, 2026
- ArthroTAK Tendon Anchor KitK262809 · ArthroTAK, LLC · Sep 2, 2026
- Iconix Knotless TK262677 · Riverpoint Medical · Aug 27, 2026
- Grappler Suture Anchor SystemK262047 · Paragon 28, Inc. · Aug 3, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 28, 1997
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3040
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files