Kinemax Plus Modular Stabilizer Femoral Component and Femoral Spacers
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer. 510(k) K963796, from Howmedica Corp. (Rutherford, NJ). Product code JWH, class 2.
As of Nov 19, 2026, K963796 is an FDA 510(k) held by Howmedica Corp., substantially equivalent on Dec 9, 1996 after 77 days, with no recalls tied to it in FDA's recall database.
- Review time: 77 days
- Recalls: 0
- Howmedica Kinemax Plus Total Knee SystemK910500 · Howmedica Corp. · May 6, 1991
- Duracon Stabilizer Femoral Component and InsertK932070 · Howmedica Corp. · Mar 22, 1995
- Duracon Modular Femoral Component and Femoral SpacK920034 · Pfizer Hospital Products Group, Inc. · Mar 18, 1992
- MicroPort Total Knee SystemK263065 · Suzhou Microport Orthorecon Co., Ltd. · Oct 29, 2026
- GMK ExtensionK262057 · Medacta International SA · Sep 15, 2026
- GSPE SpacerK260063 · The General Hospital Corporation, d/b/a Massachusetts · Sep 11, 2026
- EVOLUTION MPX™ Total Knee SystemK262293 · Suzhou Microport Orthorecon Co., Ltd. · Sep 10, 2026
- b-ONE® Mobio™ Total Knee System Revision Cemented Tibial Augments, Stem Extensions and Press-Fit Stem ExtensionsK262341 · B-One Ortho, Corp. · Sep 8, 2026
- ATTUNE Revision Knee SystemK262130 · Depuy Orthopaedics, Inc. · Sep 4, 2026
- SK Knee SystemK253961 · Just Medical Devices (Tianjin) Co., Ltd. · Sep 1, 2026
- Freedom Total Knee System (E-Poly Tibial Liners)K261563 · Maxx Orthopedics, Inc. · Aug 7, 2026
- Type
- Traditional
- Received
- Sep 23, 1996
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3560
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files