Ilizarov External Fixation System
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component. 510(k) K962808, from Smith & Nephew Richards, Inc. (Memphis, TN). Product code KTT, class 2.
As of Nov 19, 2026, K962808 is an FDA 510(k) held by Smith & Nephew Richards, Inc., substantially equivalent on Aug 19, 1996 after 32 days, with no recalls tied to it in FDA's recall database.
- Review time: 32 days
- Recalls: 0
- Cited as a predicate by: 7 devices
- FusionFrame Ring Lock SystemK200343 · Glw Medical Innovation · Sep 14, 2020
- SixFix™ Hexapod Fixator and Deformity Analysis and Correction Software (DACS)K190069 · Arrowhead De, LLC · May 14, 2019
- Smith & Nephew, Inc. External Fixation System InstrumentationK120871 · Smith & Nephew, Inc. · Jun 7, 2012
- Mdpo Frame SystemK093753 · Mdpo, LLC · Aug 26, 2010
- Smith & Nephew Circular Fixation SystemK093047 · Smith & Nephew, Inc. · Sep 27, 2010
- Carbon Fiber Composite Circular Fixation (Cirfix) Device (Half Ring)K032169 · Cyberorthology, Inc. · Sep 22, 2003
- Reprocessed External Fixation DeviceK012634 · Alliance Medical, Inc. · Jun 24, 2002
- Response Ortho Smart Fixator - Hexapod SystemK263083 · Response Ortho Solutions, LLC · Oct 2, 2026
- MAXFRAME AUTOSTRUT™ with Bluetooth Multi-Axial Correction SystemK254087 · Synthes (USA) Products, LLC · Jun 11, 2026
- DYNEX® External Fixation SystemsK260900 · Vilex, LLC · Apr 17, 2026
- QuikFix External Fixator: Knee-Spanning PackK260112 · Stabiliz Orthopaedics, Inc. · Mar 23, 2026
- Excelsior SystemK253291 · Blue Ocean Global · Jan 20, 2026
- Hoffmann LRF SystemK253202 · Stryker GmbH · Dec 19, 2025
- Monkey Rings External Ring Fixation SystemK253613 · Paragon 28, Inc. · Dec 19, 2025
- Medusa Orthopedics Boa External Fixation SystemK252555 · Medusa Orthopedics, LLC · Nov 25, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 18, 1996
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3030
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files