Cns Interchangeable Bit Cranial Drill

Drills, Burrs, Trephines & Accessories (Manual). 510(k) K961113, from Clinical Neuro Systems, LLC (Exton, PA). Product code HBG, class 2.

As of Nov 19, 2026, K961113 is an FDA 510(k) held by Clinical Neuro Systems, LLC, substantially equivalent on Jun 5, 1996 after 77 days, with 25 recalls tied to it in FDA's recall database.

  • Review time: 77 days
  • Recalls: 25+
  • Cited as a predicate by: 3 devices

Cited as a predicate

3 later 510(k) summaries name this device as a predicate
  • LegacyK252696 · Phasor Health, LLC · Nov 21, 2025
  • Evac-MriK252514 · Phasor Health, LLC · Nov 5, 2025
  • Mrii Crainial DrillK122456 · Mri Interventions, Inc. · Mar 22, 2013

Recalls

Recalls FDA ties to K961113, newest first; the 25 newest; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 17, 2024Z-1873-2024Potential holes and tears in the sterile packaging (header bag) of the Cranial Access Kit may compromise the sterility of the device.Open
Jan 19, 2024Z-1194-2024, Z-1195-2024, Z-1202-2024, Z-1200-2024, Z-1197-2024, Z-1199-2024, Z-1196-2024, Z-1193-2024, Z-1203-2024, Z-1201-2024, Z-1198-2024A defect in the sterile packaging (header bag) of the Cranial Access Kit failing the required packaging integrity testing criteria. Therefore, product sterility maybe compromised.Open
Oct 19, 2023Z-0497-2024, Z-0496-2024, Z-0498-2024, Z-0494-2024, Z-0493-2024, Z-0499-2024, Z-0495-2024Defect in the outer packaging of the Cranial Access Kits. can cause the packaging to split without any additional forces outside compromising the sterility of the deviceOpen
Oct 19, 2023Z-0492-2024, Z-0491-2024Defect in the outer packaging of the Cranial Access Kits can cause the packaging to split without any additional forces outside compromising the sterility of the deviceOpen
Aug 24, 2016Z-2733-2016Integra LifeSciences has been notified of a medical device recall by Adaptive Surgical, LLC involving their Riverlon" Nylon 3-0 Sutures that are packaged in Integras Cranial Access Kits. It was found that product seals…Terminated
Sep 4, 2013Z-2260-2013Integra is recalling certain lots of Cranial Access Kit due to a possibility that the seal integrity of the sterile package may become compromised during shipping.Terminated
Dec 21, 2011Z-0748-2012, Z-0750-2012Current package insert was revised to include additional warning information related to the potential hazards of an unapproved off-label use of Xylocaine.Terminated

Other HBG clearances

The newest 510(k)s for the same product code; see every HBG device
  • LegacyK252696 · Phasor Health, LLC · Nov 21, 2025

Record

Type
Traditional
Received
Mar 20, 1996
Review panel
Neurology
Regulation
21 CFR 882.4300

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files