Detachable Platinum Coil (Guglielmi Detachable Coil, Gdc)
Device, Neurovascular Embolization. 510(k) K951256, from Target Therapeutics (Freemont, CA). Product code HCG, class 2.
As of Nov 18, 2026, K951256 is an FDA 510(k) held by Target Therapeutics, substantially equivalent on Sep 8, 1995 after 171 days, with no recalls tied to it in FDA's recall database.
- Review time: 171 days
- Recalls: 0
- Cited as a predicate by: 6 devices
Cited as a predicate
6 later 510(k) summaries name this device as a predicate- Flipper Detachable Embolization CoilK993455 · Cook, Inc. · Jan 11, 2000
- Embolization Coil SystemK992121 · Cook, Inc. · Dec 20, 1999
- Gdc Patient Return Electtrode Model 45021K963307 · Target Therapeutics · Dec 17, 1996
- Guglielmi Detachable CoilK962503 · Target Therapeutics · Sep 20, 1996
- Amplatzer Vascular PlugK031810 · Aga Medical Corp. · Sep 9, 2003
- Trufill Dcs Detachable Coil and Frufill Dcs Syringe, Also Known As The Trufill Dcs Detachable Coil SystemK014041 · Cordis Neurovascular · Mar 7, 2002
Other HCG clearances
The newest 510(k)s for the same product code; their median review was 69 days; see every HCG device- Micrusframe (MFR100202); Micrusframe (MFR100253); Micrusframe (MFR100305); Micrusframe (MFR100356); Micrusframe…K262419 · Cerenovus, Inc. · Aug 14, 2026
- Target Xtra Detachable CoilK261772 · Stryker Neurovscular · Jun 24, 2026
- Numen™ Helia Coil Embolization System; NumenFR™ Detachment SystemK260351 · MicroPort NeuroTech (Shanghai) Co., Ltd. · May 20, 2026
- Optima Coil System (OptiOne Coil System)K254221 · Balt USA, LLC · Jan 27, 2026
- Target Detachable CoilK252694 · Stryker Neurovascular · Dec 11, 2025
- InZone IST Detachment System; IZDS Connecting CableK251832 · Stryker Neurovascular · Oct 17, 2025
- Optima Coil System (Optima Packing Coil System)K252700 · Balt USA, LLC · Sep 26, 2025
- Numen™ Coil Embolization System; NumenFR™ Detachment SystemK242154 · MicroPort NeuroTech (Shanghai) Co., Ltd. · Sep 30, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 21, 1995
- Review panel
- Neurology
- Regulation
- 21 CFR 882.5950
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files