Extracorporeal Circuit With Bio-Active Surface

Oxygenator, Cardiopulmonary Bypass. 510(k) K891687, from Medtronic Blood Systems, Inc. (Anaheim, CA). Product code DTZ, class 2.

As of Nov 21, 2026, K891687 is an FDA 510(k) held by Medtronic Blood Systems, Inc., substantially equivalent on May 31, 1989 after 70 days, with 10 recalls tied to it in FDA's recall database.

  • Review time: 70 days
  • Recalls: 10
  • Cited as a predicate by: 7 devices

Cited as a predicate

7 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K891687, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Aug 8, 2018Z-2495-2020Affected products failed a sterilization test.Terminated
Feb 4, 2016Z-1023-2016Medtronic is notifying customers who have or may receive specific lots of Medtronic Perfusion Tubing Packs that include the potentially affected cuvettes manufactured by Terumo Cardiovascular Systems (Terumo CVS).…Terminated
Aug 18, 2015Z-2736-2015Hemocor High Performance Hemoconcentrators demonstrate low ultrafiltration performance that is below product specification. These potentially affected units have been distributed as stand-alone devices and in specific…Terminated
Jul 17, 2013Z-2105-2013Medtronic was notified that Edwards Lifesciences has initiated a product recall for the Rigid Suction Wand, model S099B. The Wands are included within certain Perfusion Tubing Packs that are manufactured and distributed…Terminated
Nov 19, 2012Z-0618-2013Medtronic is initiating an Urgent Medical Device Customer Notification. We have confirmed that certain Medtronic Intersept Tubing Packs contain packaging trays that are susceptible to damage that can compromise product…Terminated
Dec 14, 2011Z-0813-2012Instructions for Use for the DLP Single Stage Venous Cannulae are in the process of being updated. The current precaution statement referencing ventricular assist procedures will be identified as a contraindication in…Terminated
May 9, 2008Z-1920-2008Medtronic is recalling selected Carmeda-coated cardiopulmonary bypass (CPB) products (e.g., oxygenators, reservoirs, pumps, cannulae and tubing packs) that were manufactured with contaminated heparin. Medtronic's…Terminated
Aug 1, 2007Z-1227-2007Medtronic Custom Tubing Packs might have open header bag seals.Terminated
Jan 2, 2007Z-0583-2007One lot of Custom Perfusion Sets, Catalog 2T10R1 was incorrectly assembled. The one way vacuum relief valve on the 102 inch line is attached backwards, thus preventing flow.Terminated
Sep 15, 2004Z-1489-04Spiral tip from DLP VAD cannula may be loose and potentially detach during use.Terminated

Other DTZ clearances

The newest 510(k)s for the same product code; their median review was 269 days; see every DTZ device

Record

Type
Traditional
Received
Mar 22, 1989
Review panel
Cardiovascular
Regulation
21 CFR 870.4350

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files