Extracorporeal Circuit With Bio-Active Surface
Oxygenator, Cardiopulmonary Bypass. 510(k) K891687, from Medtronic Blood Systems, Inc. (Anaheim, CA). Product code DTZ, class 2.
As of Nov 21, 2026, K891687 is an FDA 510(k) held by Medtronic Blood Systems, Inc., substantially equivalent on May 31, 1989 after 70 days, with 10 recalls tied to it in FDA's recall database.
- Review time: 70 days
- Recalls: 10
- Cited as a predicate by: 7 devices
- Carmeda Coated Cardiotherm Blood Cardioplegia Systems (Cbctxxx Series and Cbctxxxbr Series)K973475 · Medtronic Vascular · Nov 20, 1997
- BPX80 Bio-Pump (BPX80)K973011 · Medtronic Bio-Medicus, Inc. · Feb 25, 1998
- Tubing PackK171308 · Medtronic, Inc. · Jun 2, 2017
- Select 3D Arterial Cannula With Carmeda Bioactive Surface and Select Cap Arterial Cannula With Carmeda Bioactive SurfaceK033416 · Medtronic Perfusion Systems · Nov 5, 2003
- MC2X Multi-Stage Venous CannulaK031776 · Medtronic Perfusion Systems · Jul 25, 2003
- Medtronic Resting Heart System, Model AAR1000 and 711K031700 · Medtronic Perfusion Systems · Aug 29, 2003
- Eopa Elongated One-Piece Arterial Cannula and GuidewireK031037 · Medtronic Perfusion Systems · May 13, 2003
| Aug 8, 2018 | Z-2495-2020Affected products failed a sterilization test. | Terminated |
| Feb 4, 2016 | Z-1023-2016Medtronic is notifying customers who have or may receive specific lots of Medtronic Perfusion Tubing Packs that include the potentially affected cuvettes manufactured by Terumo Cardiovascular Systems (Terumo CVS).… | Terminated |
| Aug 18, 2015 | Z-2736-2015Hemocor High Performance Hemoconcentrators demonstrate low ultrafiltration performance that is below product specification. These potentially affected units have been distributed as stand-alone devices and in specific… | Terminated |
| Jul 17, 2013 | Z-2105-2013Medtronic was notified that Edwards Lifesciences has initiated a product recall for the Rigid Suction Wand, model S099B. The Wands are included within certain Perfusion Tubing Packs that are manufactured and distributed… | Terminated |
| Nov 19, 2012 | Z-0618-2013Medtronic is initiating an Urgent Medical Device Customer Notification. We have confirmed that certain Medtronic Intersept Tubing Packs contain packaging trays that are susceptible to damage that can compromise product… | Terminated |
| Dec 14, 2011 | Z-0813-2012Instructions for Use for the DLP Single Stage Venous Cannulae are in the process of being updated. The current precaution statement referencing ventricular assist procedures will be identified as a contraindication in… | Terminated |
| May 9, 2008 | Z-1920-2008Medtronic is recalling selected Carmeda-coated cardiopulmonary bypass (CPB) products (e.g., oxygenators, reservoirs, pumps, cannulae and tubing packs) that were manufactured with contaminated heparin. Medtronic's… | Terminated |
| Aug 1, 2007 | Z-1227-2007Medtronic Custom Tubing Packs might have open header bag seals. | Terminated |
| Jan 2, 2007 | Z-0583-2007One lot of Custom Perfusion Sets, Catalog 2T10R1 was incorrectly assembled. The one way vacuum relief valve on the 102 inch line is attached backwards, thus preventing flow. | Terminated |
| Sep 15, 2004 | Z-1489-04Spiral tip from DLP VAD cannula may be loose and potentially detach during use. | Terminated |
- HORIZON 8AF (Integrated OXY MODULE 8AF and Horizon CVR) (US5305)K261438 · Eurosets S.R.L · Sep 14, 2026
- Lifemotion Disposable Membrane OxygenatorK253838 · Lifemotion Medical Technology Co., Ltd. · Mar 16, 2026
- Quantum Perfusion Blood Oxygenator ECC VT160-E3 (VT160-E3); Quantum Perfusion Blood Oxygenator ECC VT200-E3 (VT200-E3);…K240934 · Spectrum Medical S.R.L. · Mar 12, 2026
- Horizon AF Plus System (Integrated A.L. One AF Plus OXYGENATOR and Horizon CVR) (US5300); A.L. One AF Plus OXYGENATOR…K250821 · Eurosets S.R.L · Dec 12, 2025
- Trilly Pediatric Oxygenator with Integrated Arterial Filter (US5232)K242503 · Eurosets S.R.L · Nov 24, 2025
- Quantum Perfusion Blood Oxygenator VT75-E1, Quantum Perfusion Blood Oxygenator VT75-E2K231982 · Qura S.R.L · Sep 12, 2024
- Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811); Affinity Fusion Oxygenator…K240666 · Medtronic Perfusion Systems · Jul 10, 2024
- Affinity NT Oxygenator and Uncoated Cardiotomy/ Venous Reservoir (541); Affinity NT Oxygenator with Balance Biosurface…K241352 · Medtronic, Inc. · Jun 12, 2024
- Type
- Traditional
- Received
- Mar 22, 1989
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.4350
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files