Cuffed Tracheal Tube (Multiple)
Tube, Tracheal (W/Wo Connector). 510(k) K871204, from Mallinckrodt Critical Care (Argyle, NY). Product code BTR, class 2.
As of Nov 19, 2026, K871204 is an FDA 510(k) held by Mallinckrodt Critical Care, substantially equivalent on Apr 21, 1987 after 27 days, with 1 recall tied to it in FDA's recall database.
- Review time: 27 days
- Recalls: 1
- Cited as a predicate by: 4 devices
- Shiley Extended Length, Disposable Cannula, Tracheostomy Tube: Cuffed, Distal Extension, Cuffed, Proximal Extension, CufK971267 · Mallinckrodt Medical · Sep 25, 1997
- Taperguard Endotracheal Tubes, Taperguard Evac Endotracheal TubesK090352 · Covidien · Apr 3, 2009
- Sealguard Evac Endotracheal and Endotracheal TubesK082520 · Mallinckrodt Medical · Oct 2, 2008
- Endoflex Tracheal TubeK031794 · Merlyn Associates, Inc. · Mar 12, 2004
| Started | Recall | Status |
|---|---|---|
| Feb 10, 2023 | Z-1318-2023Due to potential leaks associate with the Oral/Nasal Tracheal Tube Cuffed inflation system. | Open |
- Tenax® Laser Resistant Endotracheal TubeK251794 · Bryan Medical, Inc. · Sep 3, 2026
- Spiro-VISTAK253437 · Spiro Robotics · Jun 12, 2026
- Shiley™ Oral RAE Tracheal Tube Cuffless, Murphy Eye (113-XX) Shiley™ Nasal RAE Tracheal Tube Cuffless, Murphy Eye…K250173 · Covidien, LLC · Oct 6, 2025
- Shiley™ Oral/Nasal Tracheal Tube with TaperGuard™ Cuff Reinforced, Murphy Eye Shiley™ Tracheal Tube TaperGuard™ Cuff…K243785 · Covidien, LLC · Sep 25, 2025
- AeroJet Ventilation CatheterK243579 · Pipeline Medical Products, LLC · Aug 13, 2025
- Frova Intubating Introducer (C-CAE-14.0-70-FII); Frova Intubating Introducer (C-CAE-14.0-70-FI); Frova Intubating…K251499 · William Cook Europe Aps · Jun 11, 2025
- ProVu Single Use Video Stylet with Reinforced ET Tube (Size 6.5) (038-995-065U); ProVu Single Use Video Stylet with…K250243 · Flexicare Medical Limited. · May 20, 2025
- LMA Fastrach ETT SUK242495 · Teleflex Medical · Apr 29, 2025
- Type
- Traditional
- Received
- Mar 25, 1987
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5730
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files