[Central Venous][Multi-Lumen] Catheter W/Flex Tip

Catheter, Percutaneous. 510(k) K862056, from Arrow Intl., Inc. (Reading, PA). Product code DQY, class 2.

As of Nov 19, 2026, K862056 is an FDA 510(k) held by Arrow Intl., Inc., substantially equivalent on Aug 25, 1986 after 87 days, with 24 recalls tied to it in FDA's recall database.

  • Review time: 87 days
  • Recalls: 24
  • Cited as a predicate by: 3 devices

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K862056, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 21, 2026Z-2377-2026Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if…Open
Jan 10, 2019Z-1118-2019, Z-1119-2019The product lidstock contains a labelling error. The lidstock states the incorrect priming volume. The priming volumes printed on the extension lines are correctTerminated
Nov 14, 2018Z-0723-2019The lidstock states the incorrect priming volume and flow rates.Terminated
Jul 10, 2018Z-2818-2018, Z-2819-2018The packaging may not be sealed. If the packaging is compromised in this manner, the sterility of the product cannot be guaranteed.Terminated
May 11, 2018Z-2336-2018The recalling firm has received complaints related to increased resistance encountered when introducing the CVC over the spring wire guide. This may lead to procedural delay, and there may be need of medical…Terminated
Apr 11, 2018Z-1967-2018, Z-1982-2018, Z-1978-2018Product sterility may be compromised due to unsealed packaging.Terminated
Dec 22, 2017Z-1332-2018Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.Terminated
Oct 17, 2017Z-0654-2018, Z-0657-2018, Z-0652-2018, Z-0648-2018, Z-0650-2018These finished good kits may contain the incorrect Springwire Guide (SWG).Terminated
May 9, 2017Z-2336-2017The Arrow CVC is indicated to provide short-term (<30 days) central venous access for treatment of diseases or conditions requiring central venous access including, but not limited to: -multiple infusions of fluids,…Terminated
Sep 18, 2014Z-0076-2015Arrow International, Inc. has initiated a voluntary recall for product code AK- 12703, lot number RF3039028 because the label on the outer corrugate is labeled with the incorrect expiration date. All kits packaged…Terminated
Aug 6, 2014Z-0066-2015The component supplier recalled their 0.9% Sodium Chloride Injection USP BD Posiflush SF Saline Flush Syringe 10mL because some unit packages may exhibit open seals which impact package integrity and potentially product…Terminated
Jul 31, 2013Z-1965-2013Arrow is recalling the product due to a labeling inconsistency. One portion of the lidstock states the kit contains a 3-Lumen catheter while the rest of the lidstock correctly identifies the catheter as 2-Lumen.Terminated
Nov 9, 2010Z-0898-2011One lot of product was inadvertently mislabeled with a product lidstock identifying the product as a triple-lumen catheter with product number CV-15703, but a double-lumen catheter with part number CV-16702 was actually…Terminated
Jun 17, 2009Z-1653-2009The spring wire guide is too large in diameter to pass through the needle, dilator and catheter.Terminated
Feb 11, 2009Z-1495-2009Leakage: Material not lipid resistant, may crack and/or leak. Use of this device with lipid containing solutions or 70% isopropyl alcohol may cause leakage or air embolism.Terminated
Sep 16, 2003Z-0083-04wrong product in boxTerminated

Other DQY clearances

The newest 510(k)s for the same product code; their median review was 42 days; see every DQY device

Record

Type
Traditional
Received
May 30, 1986
Review panel
Cardiovascular
Regulation
21 CFR 870.1250

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files