Arca
Skip to content
Tools
Tools

Radiation Sterilized Admin. Set

Set, Administration, Intravascular. 510(k) K811078, from Travenol Laboratories, S.A. (Mchenry, IL). Product code FPA, class 2.

As of Nov 20, 2026, K811078 is an FDA 510(k) held by Travenol Laboratories, S.A., substantially equivalent on Jul 2, 1981 after 73 days, with 17 recalls tied to it in FDA's recall database.

  • Review time: 73 days
  • Recalls: 17
  • Cited as a predicate by: 2 devices

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K811078, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Mar 28, 2013Z-1268-2013Customers have reported that when separating an individual package from its attached grouping, the adjacent package has opened, compromising its sterile barrier properties.Terminated
Sep 9, 2010Z-0149-2011During packaging testing, Baxter observed tears and pinholes in Chevron-style pouches for certain infusion disposable products. The pinholes and tears could compromise the sterile barrier properties of the pouch.Terminated
Dec 15, 2005Z-0646-06, Z-0628-06, Z-0649-06, Z-0627-06, Z-0635-06, Z-0645-06, Z-0639-06The extension sets contain microbore female luers that may crack during use, resulting in leakage of medication or incomplete delivery of medication.Terminated
Jul 6, 2005Z-1101-05Leaks and disconnection between the bifurcated Y-site and the set tubing may occur and result in underdelivery of medication, blood loss, and a breach of the sterile fluid pathway.Terminated
Oct 17, 2002Z-0512-03, Z-0506-03, Z-0515-03, Z-0514-03, Z-0513-03, Z-0511-03, Z-0516-03The I.V. filter sets contain a 1.2 micron filter instead of the labeled 0.22 micron filter.Terminated

Other FPA clearances

The newest 510(k)s for the same product code; their median review was 266 days; see every FPA device

Record

Type
Traditional
Received
Apr 20, 1981
Review panel
General Hospital
Regulation
21 CFR 880.5440

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.