MONTAGE XT Cranial Cement
Methyl Methacrylate For Cranioplasty. 510(k) K253854, from Orthocon, Inc. (Stamford, CT). Product code GXP, class 2.
As of Nov 18, 2026, K253854 is an FDA 510(k) held by Orthocon, Inc., substantially equivalent on Jan 2, 2026 after 30 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jan 2, 2026
- Review time: 30 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFMONTAGE XT Cranial Cement is a self-setting calcium phosphate cement indicated for use in the repair of neurosurgical burr holes, contiguous craniotomy cuts, and other cranial defects with a surface area no larger than 25 \, cm^2 . MONTAGE XT Cranial Cement should be used only in skeletally mature individuals.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- MONTAGE Settable, Resorbable Bone PuttyK221933 · Orthocon, Inc. · Jan 13, 2023
- Montage-XT Settable, Resorbable Bone PuttyK233566 · Orthocon, Inc. · Aug 21, 2024
- MONTAGE-XT Settable, Resorbable Hemostatic Bone PuttyK220315 · Orthocon, Inc. · Mar 11, 2022
Other GXP Clearances
The newest 510(k)s for the same product code; their median review was 158 days; see every GXP device- TnR Cranial ImplantK251959 · T&R BIOFAB CO., Ltd. · Jul 30, 2026
- Permatage XT Settable Bone PuttyK261265 · Orthocon, Inc. · Jun 15, 2026
- Permatage Flowable, Settable Bone PasteK253732 · Orthocon, Inc. · Mar 13, 2026
- Permatage Settable Bone PuttyK241027 · Orthocon, Inc. · Sep 26, 2024
- Montage Flowable Settable, Resorbable Bone PasteK232771 · Orthocon, Inc. · Feb 16, 2024
- MONTAGE-QS Settable, Resorbable Bone PuttyK231475 · Orthocon, Inc. · Oct 12, 2023
- MONTAGE Settable, Resorbable Bone PuttyK221933 · Orthocon, Inc. · Jan 13, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Dec 3, 2025
- Review panel
- Neurology
- Regulation
- 21 CFR 882.5300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files