Suture, Absorbable, Synthetic, Polyglycolic Acid. 510(k) K252743, from ETHICON, Inc. (Raritan, NJ). Product code GAM, class 2.
As of Nov 16, 2026, K252743 is an FDA 510(k) held by ETHICON, Inc., substantially equivalent on Dec 22, 2025 after 116 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Dec 22, 2025
- Review time: 116 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe STRATAFIX™ Spiral PDS™ Plus Knotless Tissue Control Devices are indicated for use in soft tissue approximation where the use of absorbable sutures is appropriate.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- STRATAFIX Spiral PDS Plus Bidirectional Knotless Tissue Control DeviceK192144 · ETHICON, Inc. · Mar 25, 2020
- STRATAFIX Symmetric PDS Plus Knotless Tissue Control Devices, STRATAFIX Spiral PDS Plus…K182873 · ETHICON, Inc. · Jan 10, 2019
Other GAM Clearances
The newest 510(k)s for the same product code; their median review was 196 days; see every GAM device- Fast Absorbing PGLAK263073 · Riverpoint Medical, LLC · Sep 29, 2026
- Coated VICRYL (Polyglactin 910) Plus Antibacterial SutureK253394 · ETHICON, Inc. · Jun 25, 2026
- Trexon Monofilament Synthetic Absorbable SutureK253530 · Medtronic · May 28, 2026
- MONOCRYL Plus Antibacterial Poliglecaprone 25 (Monofilament), Sterile Synthetic…K253852 · ETHICON, Inc. · Feb 6, 2026
- TroClose 1200K253620 · Gordian Surgical, Ltd. · Dec 16, 2025
- PGLA90 Poly(glycolide-co-L-lactide) Surgical Sutures (Calypso); PGLA90…K252820 · Internacional Farmacéutica S.A DE C.V · Oct 3, 2025
- Monotime and Optime RK233265 · Peters Surgical · Oct 11, 2024
- Peters Surgical ADVANTIME Absorbable Suture (ADVANTIME)K232372 · Peters Surgical · Jul 12, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 28, 2025
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4493
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files