Achieva and 10 more
System, Nuclear Magnetic Resonance Imaging. 510(k) K251808, from Philips Medical Systems Nederland B.V. (Best, NL). Product code LNH, class 2.
As of Nov 19, 2026, K251808 is an FDA 510(k) held by Philips Medical Systems Nederland B.V., substantially equivalent on Jul 11, 2025 after 29 days, with 19 recalls tied to it in FDA's recall database.
- Review time: 29 days
- Recalls: 19
The indications for Use statement provided below for the subject Achieva, Intera, Ingenia 1.5T, Ingenia 3.0T, Ingenia 1.5T CX, Ingenia 3.0T CX, Ingenia Elition S, Ingenia Elition X, Ingenia Ambition S, Ingenia Ambition X and MR 5300 MR Systems is identical to the predicate devices. The intended use is also not impacted by the introduction of software changes as described in section
- Mr 5300K212673 · Philips Medical Systems Nederland B.V. · Nov 19, 2021
- Achieva, Intera, Ingenia, Ingneia CX, Ingenia Elition, and Ingenia Ambition MR SystemsK193215 · Philips Medical Systems Nederland B.V. · Apr 10, 2020
| Aug 28, 2026 | Z-3309-2026, Z-3312-2026, Z-3311-2026, Z-3314-2026, Z-3310-2026, Z-3318-2026When exporting diffusion tensor imaging (DTI) scans from a MR system using the Enhanced MR DICOM format, the exports contain incorrect data (diffusion directions). If the Enhanced MR DICOM export is used in conjunction… | Open |
| Aug 21, 2026 | Z-3243-2026, Z-3235-2026, Z-3238-2026, Z-3237-2026, Z-3239-2026, Z-3241-2026A software issue will terminate an examination during the image reconstruction process if the scan parameters are manually adjusted such that reconstruction requirements exceed the available system memory. | Open |
| Apr 14, 2026 | Z-1958-2026, Z-1959-2026, Z-1954-2026, Z-1961-2026, Z-1967-2026, Z-1963-2026The potential for stiffness value errors when a specific range of image reconstruction parameters is used in combination with Resoundant's algorithm, leading to the reconstruction voxel size settings in the default MRE… | Open |
| Dec 3, 2025 | Z-1204-2026The potential for stiffness value errors when viewing exported MR Elastography (MRE) stiffness maps to viewer Picture Archiving and Communication System (PACS). | Open |
- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 12, 2025
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files