Parietene™ Macroporous Mesh (PPM5050 )
Mesh, Surgical, Polymeric. 510(k) K250869, from Sofradim Production (Trévoux, FR). Product code FTL, class 2.
As of Nov 17, 2026, K250869 is an FDA 510(k) held by Sofradim Production, substantially equivalent on Apr 23, 2025 after 30 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Apr 23, 2025
- Review time: 30 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFParietene™ macroporous mesh is intended for the reinforcement of abdominal wall soft tissue where a weakness exists, in procedures involving abdominal wall hernias repair.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Parietene Macroporous MeshK142091 · Sofradim Production · Oct 17, 2014
- Parietene Macroporous MeshK223218 · Sofradim Production · Dec 2, 2022
- PROLENE Soft Polypropylene MeshK172089 · ETHICON, Inc. · Oct 5, 2017
Other FTL Clearances
The newest 510(k)s for the same product code; their median review was 85 days; see every FTL device- Liora Monofilament ScaffoldK260474 · TELA Bio, Inc. · Sep 28, 2026
- ProGrip advanced self-gripping polypropylene mesh (ADG1510, ADG2015, ADG3020, ADG4030)K253956 · Sofradim Production · May 21, 2026
- Parietene Flat Sheet MeshK253125 · Medtronic - Sofradim Production · Oct 24, 2025
- Onflex MeshK251955 · Davol Inc., Subsidiary of C. R. Bard, Inc. · Jul 24, 2025
- Bard® Mesh; Bard® Mesh Pre-ShapedK251557 · Davol, Inc. · Jun 12, 2025
- Bard Soft Mesh; Bard Soft Mesh Pre-ShapedK250098 · Davol, Inc. · Apr 9, 2025
- ProGrip Self-Gripping Polypropylene MeshK243315 · Sofradim Production · Jan 17, 2025
- 3DMax Light MeshK241250 · Davol Inc., Subsidiary of C. R. Bard, Inc. · Jun 14, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Mar 24, 2025
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.3300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files