Linkt Compression Staple System
Staple, Fixation, Bone. 510(k) K250712, from Trax Surgical (Stoughton, MA). Product code JDR, class 2.
As of Nov 18, 2026, K250712 is an FDA 510(k) held by Trax Surgical, substantially equivalent on May 14, 2025 after 65 days, with no recalls tied to it in FDA's recall database.
- Review time: 65 days
- Recalls: 0
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe Linkt TM Compression Staple System is intended to be used for fracture and osteotomy fixation and joint arthrodesis of the hand and foot.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- FuseForce™ Flex Dynamic Compression SystemK203832 · Wright Medical · May 7, 2021
- Medline UNITE REFLEX Nitinol Staple SystemK210482 · Medline Industries, Inc. · Apr 22, 2021
- Medline UNITE® REFLEX® Nitinol Staple SystemK231885 · Medline Industries, LP · Aug 9, 2023
Other JDR clearances
The newest 510(k)s for the same product code; their median review was 58 days; see every JDR device- Arthrex DynaNite StaplesK262451 · Arthrex, Inc. · Sep 1, 2026
- Megalodon Dynamic Compression SystemK261121 · Paragon 28, Inc. · Aug 6, 2026
- Medline UNITE® REFLEX® Hybrid Nitinol Implant SystemK243888 · Medline Industries, LP · Apr 11, 2025
- Arthrex DynaNite Nitinol StaplesK243742 · Arthrex, Inc. · Jan 31, 2025
- TMC Compression Implant SystemK243658 · Treace Medical Concepts · Dec 26, 2024
- TMC Compression Implant SystemK242415 · Treace Medical Concepts · Sep 6, 2024
- COGNiTiON™ Staple SystemK240212 · Ortho Solutions UK , Ltd. · Feb 23, 2024
- A’TOMIC™ Nitinol Fixation SystemK232990 · Rmr Ortho, LLC · Jan 12, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 10, 2025
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3030
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files