Arca
Skip to content
Tools
Tools

SCENARIA View Phase 5.0

System, X-Ray, Tomography, Computed. 510(k) K250370, from Fujifilm Corporation (Minato-Ku, JP). Product code JAK, class 2.

As of Nov 18, 2026, K250370 is an FDA 510(k) held by Fujifilm Corporation, substantially equivalent on May 20, 2025 after 99 days, with no recalls tied to it in FDA's recall database.

  • Substantially equivalent: May 20, 2025
  • Review time: 99 days
  • Recalls: 0
  • Cited as a predicate by: 2 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The SCENARIO View system is indicated to acquire axial volumes of the whole body including the head. Images can be acquired in axial, helical, or dynamic modes. The SCENARIO View system can also be used for interventional needle guidance. Volume datasets acquired by a SCENARIO View system can be post-processed in the SCENARIO View system to provide additional information.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

2 later 510(k) summaries name this device as a predicate

Other JAK Clearances

The newest 510(k)s for the same product code; their median review was 237 days; see every JAK device

Elsewhere

Record

Type
Traditional
Received
Feb 10, 2025
Review panel
Radiology
Regulation
21 CFR 892.1750

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.