OptiVu™ Shoulder
Orthopedic Augmented Reality. 510(k) K250108, from Mr Surgical Solutions, LLC (Conshohocken, PA). Product code SBF, class 2.
As of Nov 18, 2026, K250108 is an FDA 510(k) held by Mr Surgical Solutions, LLC, substantially equivalent on Jul 9, 2025 after 174 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jul 9, 2025
- Review time: 174 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFOptiVu Shoulder is intended for use during stereotaxic surgery to aid the surgeon in locating anatomical structures (humerus and scapula), humerus resection, and aligning the endoprosthesis with the anatomical structures, provided that the required anatomical landmarks can be identified on the patient’s preoperative CT scan.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Knee+K243975 · Pixee Medical · Mar 20, 2025
- NextAR RSA PlatformK210153 · Medacta International S.A. · May 12, 2021
- ROSA® Shoulder SystemK233199 · Orthosoft Inc (D/B/A Zimmer Cas) · Feb 21, 2024
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- OptiVu™ ShoulderK252170 · Mr Surgical Solutions, LLC · Aug 8, 2025
Other SBF Clearances
The newest 510(k)s for the same product code; their median review was 90 days; see every SBF device- xvision Spine systemK261854 · Augmedics, Ltd. · Jul 31, 2026
- Knee+K253805 · Pixee Medical S.A.S. · Apr 24, 2026
- NextAR Hip PlatformK252847 · Medacta International S.A. · Jan 9, 2026
- xvision Spine systemK251639 · Augmedics, Ltd. · Oct 3, 2025
- SpineAR SNAP (SyncAR Spine)K252054 · Surgical Theater, Inc. · Sep 29, 2025
- OptiVu ShoulderK252530 · Mr Surgical Solutions, LLC · Sep 10, 2025
- NextAR(TM) Shoulder PlatformK251737 · Medacta International S.A. · Sep 4, 2025
- OptiVu ShoulderK252170 · Mr Surgical Solutions, LLC · Aug 8, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 16, 2025
- Review panel
- Neurology
- Regulation
- 21 CFR 882.4560
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files