SignalNED System (Model RE)
Reduced- Montage Standard Electroencephalograph. 510(k) K242306, from Forest Devices, Inc. (Pittsburgh, PA). Product code OMC, class 2.
As of Nov 16, 2026, K242306 is an FDA 510(k) held by Forest Devices, Inc., substantially equivalent on Sep 4, 2024 after 30 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Sep 4, 2024
- Review time: 30 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe SignalNED Device is intended to record and store EEG signals and display Quantitative EEG (qEEG) (relative band power, e.g., alpha, beta, delta, theta), which is intended to help the user analyze the EEG. The SignalNED does not provide any diagnostic conclusion about the patient’s condition. The device is intended to be used on adults by qualified medical and clinical professionals.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Ceribell Pocket EEG DeviceK170363 · Ceribell, Inc. · May 8, 2017
- Lifelines iEEGK143487 · Kvikna Ehf · Aug 21, 2015
- Ceribell Instant EEG HeadbandK171459 · Ceribell, Inc. · Aug 21, 2017
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- SignalNED System (Model RE)K251726 · Forest Devices, Inc. · Sep 3, 2025
Other OMC Clearances
The newest 510(k)s for the same product code; their median review was 90 days; see every OMC device- Ceribell MonitorK261101 · Ceribell, Inc. · Jun 30, 2026
- NX01 (NX01)K251550 · Naox Technologies Sas · Nov 25, 2025
- SignalNED System (Model RE)K251726 · Forest Devices, Inc. · Sep 3, 2025
- REMI Remote EEG Monitoring SystemK243185 · Epitel · Mar 21, 2025
- Natus BrainWatch SystemK242930 · Natus Medical Incorporated Dba Excel-Tech Ltd. (Xltek) · Nov 19, 2024
- Quex Ed; Quex SK232779 · Qx World, Ltd. · Oct 11, 2024
- REMI Remote EEG Monitoring SystemK230933 · Epitel, Inc. · Jun 30, 2023
- NEBA® Compact EEG2R Mobile HeadsetK223628 · Neba Health, LLC · Mar 2, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Aug 5, 2024
- Review panel
- Neurology
- Regulation
- 21 CFR 882.1400
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files