Peripheral Mechanical Thrombectomy With Aspiration. 510(k) K241894, from Inari Medical, Inc. (Irvine, CA). Product code QEW, class 2.
As of Nov 18, 2026, K241894 is an FDA 510(k) held by Inari Medical, Inc., substantially equivalent on Oct 15, 2024 after 109 days, with 1 recall tied to it in FDA's recall database.
- Substantially equivalent: Oct 15, 2024
- Review time: 109 days
- Recalls: 1
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Artix™ MT thrombectomy device is indicated for: · The non-surgical removal of emboli and thrombi from blood vessels · Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The Artix™ MT thrombectomy device is intended for use in the peripheral vasculature.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Artix Thrombectomy DeviceK220600 · Inari Medical · Mar 25, 2022
- Artix BGK230912 · Inari Medical · May 2, 2023
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Artix™ MT;Artix™ Thin-Walled SheathK262538 · Inari Medical, Inc. · Aug 21, 2026
Recalls
Recalls FDA ties to K241894, newest first; each opens FDA's recall record| Started | Reason | Status |
|---|---|---|
| Apr 8, 2025 | Z-1728-2025Thrombectomy device specifies vessel range of 2.5-6 mm on the pouch, carton, and Instructions for Use rather than the correct vessel range of 3-6 mm, which could incrementally increase the radial force on the artery,… | Open, Classified |
Other QEW Clearances
The newest 510(k)s for the same product code; their median review was 89 days; see every QEW device- INDIGO® Aspiration SystemK262904 · Penumbra, Inc. · Oct 15, 2026
- Triever Duo CatheterK253419 · Inari Medical, Inc. · Sep 18, 2026
- Helo Max Thrombectomy System (HEL2090)K261800 · Endovascular Engineering · Sep 3, 2026
- Artix™ MT;Artix™ Thin-Walled SheathK262538 · Inari Medical, Inc. · Aug 21, 2026
- Vertex™ Thrombectomy SystemK261523 · Jupiter Endovascular · Aug 4, 2026
- INDIGO® Aspiration System – INDIGO LinkK260599 · Penumbra, Inc. · Apr 24, 2026
- INDIGO® Aspiration System - Lightning Flash Aspiration Tubing with LINKK251949 · Penumbra, Inc. · Feb 5, 2026
- CLEANER™ Vac Thrombectomy System, CLEANER™ Vac Aspiration Catheter with Handpiece, CLEANER™ Vac Aspiration CanisterK260028 · Argon Medical Devices, Inc. · Feb 5, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 28, 2024
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.5150
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files