Medline ReNewal Reprocessed Biosense Webster Webster CS Catheter with EZ Steer Technology and Medline ReNewal Reprocessed Biosense Webster Webster CS Catheter with EZ Steer Technology and Auto ID Technology (BD710DF282CT, BD710DF282RTS, BD710FJ282RTS, BD710FJ282CT)

Catheter, Recording, Electrode, Reprocessed. 510(k) K241224, from Surgical Instrument Service and Savings Inc.(Dba Medline Ren (Redmond, OR). Product code NLH, class 2.

As of Nov 20, 2026, K241224 is an FDA 510(k) held by Surgical Instrument Service and Savings Inc.(Dba Medline Ren, substantially equivalent on Nov 15, 2024 after 197 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 197 days
  • Recalls: 2

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Medline ReNewal Reprocessed Biosense Webster Webster CS Catheter is indicated for electrophysiological mapping of cardiac structures, i.e., stimulation and recording only. The catheter is designed for use in the coronary sinus.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K241224, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Dec 22, 2025Z-1319-2026These lots of reprocessed catheters may contain small particles of residual material. If affected devices are used, there is a risk of inflammatory response, systemic infection, or granulomatous reaction or thrombus…Open
Jul 31, 2025Z-2611-2025Specific lots of reprocessed electrophysiology and ultrasound catheters may contain small residual particulates. If devices with residual particulates on patient-contacting surfaces are used, there is a potential risk…Open

Other NLH clearances

The newest 510(k)s for the same product code; their median review was 141 days; see every NLH device

Record

Type
Traditional
Received
May 2, 2024
Review panel
Cardiovascular
Regulation
21 CFR 870.1220

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files