APRO 55 Catheter
Catheter, Percutaneous. 510(k) K234115, from Alembic, LLC (Mountain View, CA). Product code DQY, class 2.
As of Nov 18, 2026, K234115 is an FDA 510(k) held by Alembic, LLC, substantially equivalent on Mar 15, 2024 after 79 days, with no recalls tied to it in FDA's recall database.
- Review time: 79 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The APRO 55 Catheter is indicated for use in facilitating the insertion and guidance of appropriately sized interventional devices into a selected blood vessel in the peripheral and neurovascular systems. The APRO 55 Catheter is also indicated for use as a conduit for retrieval devices.
- AXS Catalyst Distal Access Catheter 058x115cm, AXS Catalyst Distal Access Catheter 058x132cm, AXS Catalyst Distal…K151667 · Stryker · Nov 13, 2015
- APRO 45 CatheterK251014 · Alembic, LLC · May 1, 2025
- APRO 55 Intermediate CatheterK250962 · Alembic, LLC · Apr 29, 2025
- APRO 70 Swift CatheterK243297 · Alembic, LLC · Jan 14, 2025
- CrossFAST Integrated Microcatheter Advanced Delivery SystemK262817 · Vantis Vascular, Inc. · Sep 18, 2026
- NHanceITK260559 · IMDS Operation B.V. · Aug 14, 2026
- APRO 35 Swift CatheterK262392 · Alembic, LLC · Aug 12, 2026
- CPS Locator 3D Plus Delivery CatheterK261766 · CenterPoint Systems, LLC · Jul 29, 2026
- SSPC NXT Delivery CatheterK262240 · CenterPoint Systems, LLC · Jul 29, 2026
- Amplatzer TorqVue LP Delivery System; Amplatzer TorqVue LP CatheterK261825 · Abbott · Jul 2, 2026
- Amplatzer TorqVue Exchange SystemK261631 · Abbott Medical · Jun 17, 2026
- Perfect-O Ostial Positioning CatheterK260289 · Balosmark, Inc. · Jun 5, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Dec 27, 2023
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1250
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files