Straumann CARES Visual and Nova Dental CAD
Dental Abutment Design Software For Dental Laboratory. 510(k) K233252, from Institut Straumann AG (Basel, CH). Product code PNP, class 2.
As of Nov 17, 2026, K233252 is an FDA 510(k) held by Institut Straumann AG, substantially equivalent on Dec 26, 2024 after 455 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Dec 26, 2024
- Review time: 455 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFStraumann CARES Visual/Nova Implant-borne CAD The Straumann CARES Visual/Nova Implant-borne CAD software are indicated for the design of two-piece or one- piece abutment components for single or multiple-unit implant-borne prosthetics for the restoration of partially or fully edentulous mandibles and maxillae.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Abutment DesignK200100 · 3Shape A/S · Oct 7, 2020
- Etkon ES1, Model 019.0001, Etkon Visual, Straumann Cadcam AbutmentK093113 · Institut Straumann AG · Dec 18, 2009
- Straumann TLX Implant SystemK200586 · Institut Straumann AG · Aug 20, 2020
- Straumann Variobase for Bridge/Bar CylindricalK173968 · Institut Straumann AG · Jul 17, 2018
Other PNP Clearances
The newest 510(k)s for the same product code; their median review was 459 days; see every PNP device- CloudPoint FastDesign ChairsideK231529 · Prismatik Dentalcraft, Inc. · Mar 14, 2024
- TrustK221107 · Rgorithm Korea · Jul 18, 2023
- AbutmentCADK193352 · Exocad GmbH · Jul 21, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 28, 2023
- Review panel
- Dental
- Regulation
- 21 CFR 872.3630
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files