Vy Spine™ VyLam™ Laminoplasty System
Orthosis, Spine, Plate, Laminoplasty, Metal. 510(k) K232471, from Vy Spine, LLC (Tallahassee, FL). Product code NQW, class 2.
As of Nov 17, 2026, K232471 is an FDA 510(k) held by Vy Spine, LLC, substantially equivalent on Oct 10, 2023 after 55 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 10, 2023
- Review time: 55 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Vy Spine™ VyLam™ Laminoplasty System is indicated for use in laminoplasty of the lower cervical and upper thoracic spine (C3 to T3) in skeletally mature patients. The system devices are designed for use with allogenic bone graft in order to prevent the allograft from expulsion or impinging on the spinal cord. One device may be used per vertebra.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Synthes AfsK032534 · Synthes Spine · Apr 1, 2004
- Gallery Laminoplasty Fixation SystemK100805 · Biomet Spine (Aka Ebi, LLC) · Jul 20, 2010
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Vy Spine™ VyLam™ Laminoplasty SystemK242784 · Vy Spine, LLC · Oct 16, 2024
Other NQW Clearances
The newest 510(k)s for the same product code; their median review was 61 days; see every NQW device- AQUA Laminoplasty SystemsK252930 · ZheJiang Decans Medical Devices Co., Ltd. · May 27, 2026
- Curiteva Porous PEEK Laminoplasty SystemK243137 · Curiteva, Inc. · Oct 28, 2024
- Vy Spine VyLam Laminoplasty SystemK242784 · Vy Spine, LLC · Oct 16, 2024
- Curiteva Laminoplasty SystemK231232 · Curiteva, Inc. · Jun 28, 2023
- Centerpiece Plate Fixation SystemK212428 · Medtronic Sofamor Danek · Dec 13, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 16, 2023
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files