XVISION-525, Horizon, HI-300, HI-500, Saturn-F PF32, Saturn-F PF40, Saturn-F PF50
System, X-Ray, Stationary. 510(k) K230800, from Gemss Healthcare Co., Ltd. (Paju-Si, KR). Product code KPR, class 2.
As of Nov 17, 2026, K230800 is an FDA 510(k) held by Gemss Healthcare Co., Ltd., substantially equivalent on Nov 2, 2023 after 224 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Nov 2, 2023
- Review time: 224 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe XVISION-525 diagnostic X-ray system is a stationary X-ray imaging system, for the purpose of acquiring X-ray images of the desired parts of a patient’s anatomy. This device is not intended for mammography or bone density applications.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- GXR-Series Diagnostic X-Ray SystemK192364 · DRGEM Corporation · Sep 26, 2019
Other KPR Clearances
The newest 510(k)s for the same product code; their median review was 195 days; see every KPR device- EXSYS DEXi (EXSYS DEXi-S40S); EXSYS DEXi (EXSYS DEXi-S40P); EXSYS DEXi (EXSYS DEXi-S40T);…K260227 · DRTECH Corporation · Sep 8, 2026
- MULTIX Impact; MULTIX Impact CK260488 · Siemens Medical Solutions USA, Inc. · Aug 31, 2026
- GC85AK260481 · Samsung Electronics Co., Ltd. · Aug 27, 2026
- DRE DuoK260482 · Jpi Healthcare Co, Ltd. · Jun 15, 2026
- AeroDR TX c02K253446 · Dk Medical Systems Co., Ltd. · Apr 10, 2026
- DRX-Evolution Plus X-ray System, DRX-Compass Mobile X-ray System, Lux HD 35 detector, Lux…K250954 · Carestream Health · Jan 20, 2026
- uDR Arria & uDR ArisK252000 · Shanghai United Imaging Healthcare Co., Ltd. · Nov 26, 2025
- uDR Aurora CXK251167 · Shanghai United Imaging Healthcare Co., Ltd. · Sep 19, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 23, 2023
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1680
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files