Arca
Skip to content
Tools
Tools

FaceHeart Vitals Software Development Kit (FH vitals SDK)

Software For Optical Camera-Based Measurement Of Pulse Rate, Heart Rate, Breathing Rate, And/Or Respiratory Rate. 510(k) K223622, from Faceheart Corp. (Grand Cayman, KY). Product code QME, class 2.

As of Nov 19, 2026, K223622 is an FDA 510(k) held by Faceheart Corp., substantially equivalent on Sep 1, 2023 after 270 days, with no recalls tied to it in FDA's recall database.

  • Review time: 270 days
  • Recalls: 0
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The FH Vitals SDK is designed to measure the pulse rate based on the given facial video stream. It is intended for non-invasive spot measurements of pulse rate when the subject is still. This SDK is not intended for use in patients with known or suspected heart arrhythmias. While the SDK can be used for general healthcare, it is not designed to treat patients.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF
  • Vital SignsK211906 · Oxehealth Limited · Jul 20, 2021

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Other QME clearances

The newest 510(k)s for the same product code; their median review was 203 days; see every QME device

Elsewhere

Record

Type
Traditional
Received
Dec 5, 2022
Review panel
Cardiovascular
Regulation
21 CFR 870.2785

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.