TNI Clear-Guard™ 3 angled breathing filter (1545020)
Filter, Bacterial, Breathing-Circuit. 510(k) K223258, from Intersurgical , Ltd. (Berkshire, GB). Product code CAH, class 2.
As of Nov 17, 2026, K223258 is an FDA 510(k) held by Intersurgical , Ltd., substantially equivalent on Jun 15, 2023 after 237 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jun 15, 2023
- Review time: 237 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFTo be used only as part of the softFlow® 50 device to protect the patient, care provider, equipment, or all three from the transference of bacteria or virus through the breathing circuit. The filter should be positioned in a non-humidified gas flow.
Other CAH Clearances
The newest 510(k)s for the same product code; their median review was 264 days; see every CAH device- Iso-Gard Filter Straight; Humid-Vent Filter Compact AngledK252643 · Teleflex Medical Sdn. Bhd. · May 15, 2026
- Ambu® Virobac II® Exhalation FilterK251583 · Ambu A/S · Apr 30, 2026
- Besmed Bacterial Filter and HMEFK241339 · Besmed Health Business Corp · Nov 14, 2024
- Breathing circuit bacterial/viral filterK222917 · Shaoxing Haitech Medical Products Co., Ltd. · Feb 15, 2024
- Passy Muir Tracheostomy Viral & Bacterial Airway Protection Filter (PM-APF15)K230483 · Passy-Muir, Inc. · Sep 16, 2023
- Filter and HME/FilterK221472 · Ningbo Huakun Medical Equipment Co., Ltd. · Feb 8, 2023
- Filter CareStar Plus, Filter SafeStar Plus, Filter/HME TwinStar PlusK221836 · Drägerwerk AG & Co. KGaA · Dec 7, 2022
- EasyOne FilterK221250 · Ndd Medizintechnik AG · Nov 22, 2022
Record
- Type
- Traditional
- Received
- Oct 21, 2022
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5260
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files