CO2 Mainstream Sensor
Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase. 510(k) K221118, from Draegerwerk AG & CO Kgaa (Luebeck, DE). Product code CCK, class 2.
As of Nov 19, 2026, K221118 is an FDA 510(k) held by Draegerwerk AG & CO Kgaa, substantially equivalent on Apr 5, 2023 after 352 days, with no recalls tied to it in FDA's recall database.
- Review time: 352 days
- Recalls: 0
- Cited as a predicate by: 1 device
Intended use The Dräger CO2 Mainstream Sensor is a sensor for measuring the CO2 concentration in breathing gas (CO2 mainstream sensor). Indications The CO2 mainstream sensor enables the diagnosis and monitoring of patients by measuring CO2. The use of the medical device is limited to one patient at a time.
- Infinity McAble - Mainstream CO2K100941 · Draeger Medical AG & Co. KG · Apr 23, 2010
- Infinity® Acute Care System (IACS) – VG8.1K260579 · Draeger Medical Systems, Inc. · Aug 20, 2026
- GF-310R Multigas Unit (GF-310R)K251641 · Nihon Kohden Corporation · Aug 12, 2026
- VisuBreathK261633 · Affirm Medical Technologies II, LLC · Jul 14, 2026
- Capnostream™35 Portable Respiratory Monitor (PM35MN)K253030 · Covidien, LLC · May 1, 2026
- Medical Gas Analyzer (AG200)K250148 · Prior Care Science Technology, Ltd. · Aug 28, 2025
- TG-980P CO2 Sensor Kit (TG-980P); TG-980P1 CO2 Sensor Kit (TG-980P1)K243956 · Nihon Kohden Corporation · Jun 10, 2025
- 0184 CO2 Sampling line; 0184T CO2 Sampling line; 0139 CO2 Sampling line; 0182 CO2 Sampling lineK251216 · Barbaras Development, Inc. · Jun 4, 2025
- Aim (N/A)K240937 · Inventeur, LLC · Dec 16, 2024
- AirLife™ Open Et Oxygen Mask, AirLife™ Open Et+ Oxygen MaskK230915 · Vyaire Medical, Inc. · Nov 12, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 18, 2022
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.1400
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files