Counter, Differential Cell. 510(k) K220031, from Abbott Laboratories (Santa Clara, CA). Product code GKZ, class 2.

As of Nov 19, 2026, K220031 is an FDA 510(k) held by Abbott Laboratories, substantially equivalent on Aug 4, 2023 after 576 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 576 days
  • Recalls: 2
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Alinity h-series System is an integrated hematology analyzer (Alinity hq) and slide maker stainer (Alinity hs) intended for screening patient populations found in clinical laboratories by qualified health care professionals. The Alinity h-series System can be configured as: • One standalone automated hematology analyzer system.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K220031, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Sep 18, 2025Z-0489-2026Software issue for hq analyzer results in system not visibly applying appropriate flagging to results when saturation is present which may result in incorrect results.Open
Jun 14, 2024Z-2681-20241)If Complete Blood Count with differential and reticulocyte(CBC+Diff+Retic) sample is run, then immediately following on same rack CBC+Diff sample is run, then falsely low red blood cell count may occur, generating…Open

Other GKZ clearances

The newest 510(k)s for the same product code; their median review was 188 days; see every GKZ device

Record

Type
Traditional
Received
Jan 5, 2022
Review panel
Hematology
Regulation
21 CFR 864.5220

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files