KardiaMobile Card
Transmitters And Receivers, Electrocardiograph, Telephone. 510(k) K211668, from AliveCor, Inc. (Mountain View, CA). Product code DXH, class 2.
As of Nov 19, 2026, K211668 is an FDA 510(k) held by AliveCor, Inc., substantially equivalent on Nov 30, 2021 after 182 days, with no recalls tied to it in FDA's recall database.
- Review time: 182 days
- Recalls: 0
The KardiaMobile Card System is intended to record, store and transfer single-channel electrocardiogram (ECG) rhythms. The KardiaMobile Card System also displays ECG rhythms and output of ECG analysis from AliveCor's KardiaAI platform including detecting the presence of normal sinus rhythm, atrial fibrillation, bradycardia, tachycardia, and others.
- KardiaMobile, KardiaStationK191406 · AliveCor, Inc. · Jan 24, 2020
- Triangle SystemK183319 · AliveCor, Inc. · May 10, 2019
- KardiaMobile, KardiaStationK182396 · AliveCor, Inc. · Apr 12, 2019
- KardiaAIK201985 · AliveCor, Inc. · Nov 12, 2020
- PreemptiveAI Clinical SDKK250233 · Measure Labs, Inc. (Dba Preemptiveai, Inc.) · Feb 13, 2026
- HeartBeam AIMIGo with 12-L ECG Synthesis Software SystemK250258 · Heartbeam, Inc. · Dec 8, 2025
- MEMO Patch M (MPT-E08R-UNC01)K243438 · Huinno Co., Ltd. · Dec 5, 2025
- Hexoskin Medical System (7100-00016)K243981 · Carre Technologies, Inc. · Nov 18, 2025
- VitalSigns 1-Lead Holter (VSH101)K243003 · VitalSigns Technology Co., Ltd. · Jun 17, 2025
- QT Ecg (Qterd100)K233521 · QT Medical, Inc. · Dec 6, 2023
- V-Patch Cardiac MonitorK222842 · Shandong Corecare Technology Limited · Oct 20, 2022
- QT EcgK220795 · QT Medical, Inc. · Sep 26, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 1, 2021
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2920
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files