Q Patch
Electrocardiograph, Ambulatory (Without Analysis). 510(k) K210758, from Medicalgorithmics S.A. (Warsaw, PL). Product code MWJ, class 2.
As of Nov 17, 2026, K210758 is an FDA 510(k) held by Medicalgorithmics S.A., substantially equivalent on Jun 2, 2022 after 444 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jun 2, 2022
- Review time: 444 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Medical algorithmics' Q Patch is intended to be used by patients who have a demonstrated need for extended cardiac monitoring and patients with symptoms that may be due to cardiac arrhythmias such as, dizziness, lightheadedness, shortness of breath, palpitations, dyspnea (shortness of breath), anxiety, syncope of unknown etiology in which arrhythmias are suspected or need to be excluded.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- my Patch slK163535 · Dms-Service, LLC · Feb 22, 2017
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- ZywieZ3 Sensor & AdhesiveK252839 · Zywie, Inc. · Jun 18, 2026
Other MWJ Clearances
The newest 510(k)s for the same product code; their median review was 270 days; see every MWJ device- Wearable ECG Recorder (YMHeart XY-12); Wearable ECG Recorder (YMHeart XY-1201); Wearable…K254119 · Shenzhen Xinyan Medical Technology Co.,ltd. · Sep 11, 2026
- Peerbridge COR MDx (Cor MDx)K253529 · Peerbridge Health, Inc. · Sep 4, 2026
- medilogFDK253562 · Schiller AG · Aug 14, 2026
- mobiCARE Cardiac Monitoring System (mobiCARE-MC200M, mobiCARE-MC200ML, mobiCARE-MC200M7,…K253384 · Seers Technology Co., Ltd. · Jun 25, 2026
- ZywieZ3 Sensor & AdhesiveK252839 · Zywie, Inc. · Jun 18, 2026
- HeartBeam AIMIGo(TM) SystemK231424 · Heartbeam, Inc. · Dec 13, 2024
- ASSURE Wearable ECGK233864 · Kestra Medical Technologies, Inc. · May 7, 2024
- S-Patch (S-Patch ExL)K233906 · Wellysis Corp. · Feb 16, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 15, 2021
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2800
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files